RclVWin
Syntax: RclVWin {<variable name> ; <folder name\
file name>}
Function: Recalls View Window values, which were
previously saved under the specified name.
Description: A folder path can be specified only up to
one level.
Receive38k
Syntax: Receive38k <variable name>
Function: Receives Data Logger data.
Description:
• The OpenComPort38k command must be executed
before this command is executed.
• The CloseComPort38k command must be
executed after this command is executed.
• For details about using this command, see the user
documentation that comes with the EA-200.
• Note that you need to replace all instances of the
Receive command in the examples provided in
the EA-200 user documentation with the command
Receive38k. You should also adjust the other
commands in the EA-200 examples so they conform
to the ClassPad command syntax and usage as
described in this manual.
Rename
Syntax: Rename <current variable name>, <new
variable name>
Function: Renames a variable.
Return
Syntax: Return {<variable>}
Function 1 (Main Program): Terminates program
execution.
Function 2 (Subroutine Program): Returns from a
subroutine.
Tip
• The Return command can be executed during an If, For,
Do, While, or Switch process.
• Appending a <variable> to the Return command in
the Main application and executing the command will
cause the variable to be displayed when the program is
complete.
S
Scatter
Function: Used as a StatGraph command argument
to specify an option. See StatGraph.
Misc - Graph&Table(2)
I/O - Communication
Misc - Variable
Ctrl - Control
Misc - Statistics(1) - Graph
Send38k
Syntax: Send38k <variable name>
Function: Sends Data Logger data.
Description:
• The OpenComPort38k command must be executed
before this command is executed.
• The CloseComPort38k command must be
executed after this command is executed.
• For details about using this command, see the user
documentation that comes with the EA-200.
• Note that you need to replace all instances of the
Send command in the examples provided in the
EA-200 user documentation with the command
Send38k. You should also adjust the other
commands in the EA-200 examples so they conform
to the ClassPad command syntax and usage as
described in this manual.
• <variable name> must be a variable that contains
a real number or a list. Anything else results in an
error.
SendVar38k
Syntax: SendVar38k <variable name>
Function: Sends variable names and variable
contents.
Description:
• The OpenComPort38k command must be executed
before this command is executed.
• The CloseComPort38k command must be
executed after this command is executed.
SeqSelOff
a
Syntax: SeqSelOff {
a
b
c
E ;
E ;
E}
n
n
n
Function: Deselects the specified sequence
expression. Specifying "
argument activates [Explicit]. Specifying any other
argument activates [Recursive].
SeqSelOn
a
Syntax: SeqSelOn {
a
E ;
b
E ;
c
E}
n
n
n
Function: Selects the specified sequence expression.
a
b
Specifying "
E", "
E", or "
n
n
activates [Explicit]. Specifying any other argument
activates [Recursive].
SeqType
n
Syntax: SeqType {"
" ; "
a
a
"
"}
n
+2
1
Function: Specifies the recursion type.
Description: Specifying "
[Explicit]. Specifying any other argument activates
[Recursive].
Chapter 12: Program Application  218
Chapter 12: Program Application  218
I/O - Communication
I/O - Communication
Misc - Sequence
a
b
b
c
;
;
;
;
n
+1
n
+2
n
+1
n
+2
n
+1
a
b
c
E", "
E", or "
E" as the
n
n
n
Misc - Sequence
a
b
b
c
;
;
;
;
n
+1
n
+2
n
+1
n
+2
n
+1
c
E" as the argument
n
Misc - Sequence
a
a
a
a
a
" ; "
" ; "
n
+1
0
n
+1
1
n
n
" as the argument activates
c
;
;
n
+2
c
;
;
n
+2
a
" ;
+2
0

Advertisement

Table of Contents
loading

Table of Contents