Battery Power
Correcting the Battery Display (Battery Recalibration)
The "Battery Recalibration" function measures and memorizes the battery capacity. To correct the battery display, use this
function to fill the battery and then discharge it completely. Perform the procedure at least once immediately after purchasing
the computer. Normally the interval of "Battery Recalibration" is three months. The battery display may not be correct when
the battery pack deteriorates after a long time use. In this case, perform the procedure again.
1
Connect the AC adaptor.
2
Close all the applications.
3
Perform "Battery Recalibration".
A
Click [start] - [All Programs] - [Panasonic] - [Battery] - [Battery Recalibration].
B
When the confirmation message appears, click [Start].
Frequent recalibration of the battery can degrade the battery. A caution message appears when the "Battery
Recalibration" is performed at the shorter interval than approximately a month. In this case, cancel the "Bat-
tery Recalibration".
C
When the message requests shut down of Windows, click [Yes].
The "Battery Recalibration" starts.
After the battery pack is fully charged, discharging starts. When the discharging is completed, the power goes off
automatically.
After the "Battery Recalibration" is finished, normal charging starts.
CAUTION
Do not close the LCD while "Battery Recalibration" is being executed.
NOTE
The temperature range should be 10
The "Battery Recalibration" may take a long time due to the large battery capacity. This is not a malfunction.
• Full charge: Approximately 5 hours [MAX]
• Complete discharge: Approximately 4.5 hours
"Battery Recalibration" does not increase the battery's capacity. If "Battery Recalibration" is executed frequently, dete-
rioration of the battery may result.
If you have two or more battery packs, perform the "Battery Recalibration" for each battery pack.
If the computer is turned off during the "Battery Recalibration" (e.g., due to power failure, or accidental removal of the
AC adaptor and battery pack), the "Battery Recalibration" will not be completed.
You can also perform the "Battery Recalibration" with the following procedure.
A
Restart the computer.
°
°
°
°
C to 30
C {50
F to 86
F}.