DIAGNOSTIC STATUS CODES
TRANSISTOR PUMP CONTROL
PUMP
DESCRIPTION OF STATUS
STATUS CODE
Open thermal protector (TP1) or
-141
transistor is over temperature.
MEMORY RECALL
NO
SYMPTOM:
Circuits valid
Reduced or no power to pump motor in
for
control range.
Pump
Controller
POSSIBLE CAUSE:
Control is in thermal cut-back.
•=Allow control to cool, status code
should disappear.
•=
If control cools to ambient
temperature and the fault remains
when the control is restarted, replace
the control.
PUMP
DESCRIPTION OF STATUS
STATUS CODE
Pump Controller "motor current sensor"
-142
input is missing.
MEMORY RECALL
NO
SYMPTOM:
Circuits valid
No power to pump motor in control
for
range.
Pump
Controller
POSSIBLE CAUSE:
Defective controller unit.
•=Replace control.
CORRECTIVE ACTIONS
CORRECTIVE ACTIONS
CAUSE OF STATUS INDICATION
This status code is displayed when the internal
heatsink temperature of the control exceeds 90
degrees.
TROUBLE-SHOOTING DIAGRAM
NO
GRAPHIC
FOR THIS
STATUS CODE
CAUSE OF STATUS INDICATION
This status code is displayed when the voltage at the
current sensor is greater than 0.1 volts with no current
flowing in the motor circuit.
TROUBLE-SHOOTING DIAGRAM
NO
GRAPHIC
FOR THIS
STATUS CODE