10-6 Damper
Function
The damper supplies cold air from the freezer to the chill room using the damper plate. The
chill room is colder when the damper plate is open. When the damper is closed the chill
rooms temperature will rise.
How to
Measure
Blue
1
2
Red
2
Check the
Check to see if there is electrical current, if there is resistance the damper is good.
Standard
Damper
Red and Yellow
Yellow
4
White
3
Red
Yellow
4
,
2
4
Test Points
Result
270~330 Ω
< Damper Circuit >
Check the
Check the
Test Points
Blue and White
-96-
Blue
1
White
3
,
1
3
,
1
3
Result
270~330 Ω