Advertisement

Freezer Fan Error (E IF)
1
Reset the unit and
Input Test1 Mode.
(Push the button 1 time)
2
Open the f reezer door and Check
the air f low. Windy?
No
Go to 4
3
Check the Fan motor.
Rotate f an using hand.
It f eel sticky?
Fan Motor
4
Check the Fan Motor voltage
Is Fan Motor voltage 11.4~12.6V?
Yes
Go to 3
5
Check the Fan Motor voltage
Is Fan Feed Back voltage 0V, 5V?
6
Change the
Check the Fan Motor voltage
Yes
Fan motor
Is Fan PWM voltage 0V, 5V?
7
Explain to customer
-50-
Voltage [V]
TEST MODE 1
CON3
11.4~12.6V
24th pin ~ 21st pin
Yes
TEST MODE 1
Voltage [V]
CON3
Not 0V, 5V
22nd pin ~ 21st pin
No
TEST MODE 1
Voltage [V]
CON3
Not 0V, 5V
23rd pin ~ 21st pin
No
Replace
No
Main PCB
Change the
Yes
motor
Replace
Yes
Main PCB
Copyright © 2019 LG Electronics Inc. All rights