Bryant 935CA Installation, Start-Up, Operating And Service And Maintenance Instructions page 22

Single-stage, upflow/horizontal communicating, variable speed ecm, ultra low nox, 35-in tall condensing gas furnace
Table of Contents

Advertisement

935CA: Installation, Start-up, Operating and Service and Maintenance Instructions
Unit Size:
Clg/CF Switch settings
5
30080C21
Clg Switches:
SW2-3
Clg Default:
OFF
CF Switches
SW3-3
Low-Clg Default:
OFF
OFF
OFF
Cooling
ON
(SW2)
ON
ON
Low-Cooling
ON
(SW3)
Maximum Clg Airflow
CF Switches
SW3-3
Cont. Fan Default:
OFF
OFF
OFF
OFF
Continuous Fan
ON
(SW3)
ON
ON
ON
Heating (SW1)
Heat Airflow
Unit Size:
Clg/CF Switch settings
6
66100C21
Clg Switches:
SW2-3
Clg Default:
OFF
CF Switches
SW3-3
OFF
OFF
Cooling
OFF
(SW2)
ON
ON
Low-Cooling
ON
(SW3)
ON
Maximum Clg Airflow
CF Switches
SW3-3
Cont. Fan Default:
OFF
OFF
OFF
OFF
Continuous Fan
ON
(SW3)
ON
ON
ON
Heating (SW1)
Heat Airflow
1.Nominal 350 CFM/ton cooling airflow is delivered with SW1-5 and SW4-3 set to OFF.
Set SW1-5 to ON for nominal 400 CFM/ton (+15% airflow).
Set SW4-3 to ON for nominal 325 CFM/ton (-7% airflow).
Set both SW1-5 and SW4-3 on ON for nominal 370 CFM/ton (+7% airflow).
The above adjustments in airflow are subject to motor horsepower range/capacity
This applies to Cooling and Low-Cooling airflow, but does not affect continuous fan airflow.
2.Maximum cooling airflow is achieved when switches SW2-3, SW2-2, SW2-1 and SW1-5 are set to ON, and SW4-3 is set to OFF.
3.All heating CFM's are when comfort/efficiency adjustment switch (SW1-4) is set to OFF
4.Ductwork must be sized for high-heating CFM within the operational range of ESP. Operation within the blank areas of the chart is not recommended because heat operation will be above
1.0 ESP.
5.All airflows on noted 21" (533 mm) casing size furnaces are 5% less on side return only installations.
6.Side returns for noted models, require two sides, or a side and bottom to allow sufficient airflow at the return of the furnace.
7.Airflows over 1800 CFM require bottom return, two-side return, or bottom and a side return or excessive watt draw may result. A minimum filter size of 20 x 25" (508 x 635 mm) is
required.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Table 11 – Air Delivery - CFM (With Filter) (Continued)
4
COOLING
AND HEATING AIR DELIVERY - CFM (Bottom Return With Filter)
(SW1-5 and SW4-3 set to OFF, except as indicated. See notes 1 and 2)
SW2-2
SW2-1
0.1
OFF
OFF
1825
1830
SW3-2
SW3-1
OFF
ON
695
700
ON
OFF
870
885
ON
ON
1045
1060
OFF
OFF
1310
1315
OFF
ON
1470
1475
ON
OFF
1825
1830
ON
ON
2170
2180
2
2230
2225
SW3-2
SW3-1
OFF
OFF
695
700
OFF
ON
695
700
ON
OFF
870
885
ON
ON
870
885
OFF
OFF
870
885
OFF
ON
870
885
ON
OFF
870
ON
ON
870
3
1425
1430
SW2-2
SW2-1
0.1
OFF
OFF
1765
1775
SW3-2
SW3-1
OFF
ON
630
ON
OFF
805
830
ON
ON
1065
1075
OFF
OFF
1240
1250
OFF
ON
1410
1415
ON
OFF
1765
1775
ON
ON
2115
2115
2
2165
2185
SW3-2
SW3-1
OFF
OFF
630
OFF
ON
630
ON
OFF
805
830
ON
ON
1020
1040
OFF
OFF
1020
1040
OFF
ON
1020
1040
ON
OFF
1020
1040
ON
ON
1020
1040
3
1790
1800
External Static Pressure (ESP)
0.2
0.3
0.4
0.5
1830
1825
1825
880
880
1070
1070
1070
1315
1315
1310
1480
1480
1480
1830
1825
1825
2180
2175
2170
2235
2230
2195
880
880
880
880
880
880
880
880
885
880
880
885
880
880
1435
1435
1435
External Static Pressure (ESP)
0.2
0.3
0.4
0.5
1790
1805
1810
1080
1085
1265
1270
1270
1435
1445
1450
1790
1805
1810
2125
2140
2145
2200
2215
2225
1050
1050
1050
1050
1050
1815
1830
1835
22
0.6
0.7
0.8
1825
1815
1810
1805
Note 4
Note 4
1070
Note 4
1300
1290
1280
1475
1465
1460
1450
1825
1815
1810
1805
2150
2080
1995
1915
2165
2110
2020
1935
Note 4
Note 4
Note 4
Note 4
Note 4
Note 4
Note 4
Note 4
1425
1420
1410
1400
0.6
0.7
0.8
1820
1820
1820
1820
Note 4
Note 4
Note 4
Note 4
1455
1460
Note 4
1820
1820
1820
1820
2150
2145
2140
2080
2240
2250
2210
2120
Note 4
Note 4
Note 4
Note 4
Note 4
Note 4
Note 4
Note 4
1845
1850
1850
1855
0.9
1.0
1785
Note 4
1440
1785
1825
1845
1390
0.9
1.0
1820
1820
1985
2030
1855