1.0 Kit Contents Note: Visually inspect all components. If any component is missing or appears damaged, do not install. Call 3M customer service at 1-800-426-8688 for a replacement product. Kit Contents SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 80-6113-2344-7 A. Cable Addition Bracket Assembly (1) B.
Page 3
3.0 Cable Addition Bracket Assembly Installation Remove screw on the 3M Scotchlok Shield Bond ™ ™ Connector 4464 and swing the plate to the side. If the shield connector is installed with rivets, do not perform this step. Remove central strength member retainer. Unscrew and remove the central strength member retainer that is intended for use.
Page 4
4.0 Grommet Assembly Installation using the 3M Scotchlok 4460-D/FO-CSM ™ ™ For LBT Please refer to instruction manual 78-0013- 2695-4 3M Scotchlok Shield Bond Connector Assembly 4460-D/FO-CSM for LBT for installation instructions. Assembly is now ready to place in the end seal of the closure or terminal.
Page 5
Using the supplied hose clamp, secure cables to the cable addition bracket and cable management tray frame as shown. Tighten hose clamp between 25 to 30 in.-lbs. (2.9 to 3.5 kgf-m). If a single cable entry is also employed through second endseal port, please refer to instruction manual number 78-8135-4502-3 for cable installation section 4.0.
Page 6
Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture for a period of one (1) year from the time of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.