Simulated Resistive Device Testing - Bradford White PDV Series Service Manual

Residential & light duty commercial power direct vent models
Hide thumbs Also See for PDV Series:
Table of Contents

Advertisement

Condensing PDV Series

Simulated Resistive Device Testing

Step 1. Position the power switch on the gas
control to the "OFF" position.
Step 2. Disconnect flammable vapor sensor
or simulated resistive device from
the gas control (model dependant).
Step 3. Using a multi-meter set to the ohms
setting, check resistance of the
flammable vapor sensor or simulated
resistive device. Resistance must be
between 3,000 ohms and 48,000
ohms. If outside of this range,
replace the simulated resistive
device.
DO NOT use a standard multi-meter probe for this
test. Doing so will damage connector. Use
special pin type electronic probes or small
diameter wire pins inserted into connector.
28
28
CAUTION
Service Procedure VII
Service Procedure VI
Simulated Resistive
Gas Control Testing and
Device Testing
Replacement

Advertisement

Table of Contents
loading

Table of Contents