Drying; Control Of The Temperatures Of The Temperature Sensors; Alarm Signals - Porkka Future Installation And Operation Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 18
Reset the alarm signal by pressing any button.

Drying

Push the button
once and the drying function of the
eventual humidity condensed on the inner surfaces starts.
During the drying function the fan and compressor of the
evaporator are on at the same time. Push the button
and the equipment will return to the normal mode.

Control of the temperatures of the temperature sensors

With Probe button (
) you can browse the temperatures of
the sensors in use. Push the button once and the display shows
the Pb1 message and immediately after that the temperature of
the sensor. Push the button again and the temperature of the
next sensor in use will be displayed. The equipment returns to
the normal mode after 15 seconds.
Pb1
initiating probe, temperature of the evaporator air
Pb2
evaporator probe, surface temperature of evaporator
(not in chiller cabinets C)
Pb3
condenser probe, surface temperature of condenser
Pb4
control probe, air temperature (in case the cabinet has
an additional probe Pb4 the value is displayed)

ALARM SIGNALS

CODE
REASON
"HA"
High temperature alarm
The temperature inside the cabinet has exceeded
the set alarm temperature. The alarm can be
instigated by sudden icing of the evaporator.
Initiate manual defrosting (see instructions on
page 4). Ensure the cabinet has not been loaded
with warm product. Check that a door has not
been left open. Check that product is not blocking
air circulation within the cabinet.
"LA"
Low temperature alarm
The temperature inside the cabinet has fallen
below the set value. Ensure that the products put
into the cabinet are not too cold.
The temperature alarm will reset automatically
after the interior of the cabinet returns to set
temperature range. If this does not happen,
move the product to another cabinet and
contact your service provider.
"dA"
Door open alarm
Only in models equipped with the door switch.
Close the door carefully and the alarm will reset
automatically.
"cSd"
Condenser alarm
The condenser/fi lter needs to be cleaned.
Switch cabinet to standby mode, remove cover
and clean the fi lter by washing and or using a
soft brush and vacuum cleaner remove dirt and
debris from the condenser face. Check also that
air circulation to the condenser is not blocked or
that the ambient temperature is not too high. If
the alarm still does not stop, remove product to
another cabinet and contact your service provider.