E. Good Faith Wall Surface/TV Guidelines
Good Faith Guidelines for TV Installa�on's above a Typical Gas Fireplace
TV on the wall
Notes:
1. These are good faith recommended clearances only and not a guarantee of compliance with all TV
manufacturers' maximum allowable operating temperatures.
2. Since every home has unique air ow characteristics and maximum allowable operating temperatures
can vary from manufacturer to manufacturer and from model to model, actual TV temperatures should be
validated at the time of each installation. TVs should not be used in situations where the actual TV
temperature exceeds the manufacturers' maximum allowable operating temperatures identi ed in the
TV's technical speci cations. Contact the TV's manufacturer directly if you cannot locate this information
or have questions regarding the information.
3. Mantel height and depth must conform to mantel requirements speci ed in the replace installation
manual.
4. "A" dimension taken from the top of the rebox opening.
5. Suggestions on how to further reduce TV temperatures:
-Increase "A" and/or 24" minimum TV height dimensions.
Figure 3.4 Good Faith Guidelines
Combus�ble Mantel
Non-Combus�ble Mantel
TV
6" Min.
A Min.
12" Min.
Monessen • BUF32/36/42 Owner's Manual • 4139-900 • Rev A • 01/21
A
inch 17.00
mm 432
inch 12.00
mm 305
24" Min.
TV recessed into the wall
TV
12" Min.
24" Min.
A Min.