General Data - Carrier 39TF Manual

Ac fan mini air handling unit-ceiling concealed type
Table of Contents

Advertisement

General Data

General Data - 39TF-B/D
Return air condition
Air
Model
Rated
Rated
Flow
Cooling
Heating
Capacity
Capacity
39TF
m
3
/h
kW
kW
010
1000
5.1
10.2
015
1500
8.3
15.2
020
2000
11.5
21.2
025
2500
14.4
26.0
030
3000
17.5
32.0
040
4000
23.4
41.5
050
5000
28.3
51.4
060
6000
34.5
61.7
070
7000
40.3
71.3
080
8000
46.2
83.1
090
9000
52.1
93.1
105
10500
59.9
108.1
120
12000
69.3
131.7
135
13500
76.8
146.6
150
15000
85.3
162.8
NOTE:
1. Cooling capacity is based on the following:
a) Inlet and outlet water temperature: 7°C/12°C
2. Heating capacity is based on the following (with the same water flow rate as cooling mode):
a) Inlet and outlet water temperature: 60°C/50°C
3. The manufacturer reserves the rights to make changes to the above specifications without prior notice.
4. The water flow in the above table indicates the cold water supply flow. Because the hot water supply flow is smaller than cold water supply flow, cold water
supply flow is provided in the table for your reference to select the water pump.
8
CARRIER
4Rows
Water
Water
Chilled
Motor
Flow
Pressure
Water
Power
Rate
Drop
Pipe
I/s
kPa
kW
DN
0.24
3.0
0.18
32
0.40
9.0
0.32
32
0.55
11.0
0.32
32
0.69
18.0
0.55
32
0.83
31.0
0.75
32
1.13
60.0
1.1
40
1.37
40.0
1.5
40
1.64
47.0
1.5
40
1.92
66.0
2.2
40
2.20
58.0
2.2
40
2.48
79.0
3.0
40
2.85
51.0
3.0
50
3.30
57.0
4.0
50
3.66
56.0
4.0
50
4.06
51.0
5.5
50
b) Air entering condition: 27°C DB/19.5°C WB
b) Air entering condition: 15°C DB
6Rows
Rated
Rated
Water
Water
Cooling
Heating
Flow
Pressure
Capacity
Capacity
Rate
Drop
kW
kW
I/s
kPa
7.2
12.4
0.34
8.8
11.0
18.5
0.52
19.5
14.9
25.3
0.71
26.0
18.2
30.8
0.87
38.0
22.0
37.3
1.05
62.0
30.1
49.1
1.43
49.5
35.2
61.8
1.68
78.0
43.7
73.9
2.08
44.0
49.4
85.3
2.35
59.0
57.6
98.3
2.74
56.0
64.8
110.3
3.09
25.4
75.1
135.3
3.58
39.0
85.8
161.1
4.09
44.0
102.3
176.4
4.87
42.0
108.5
189.7
5.17
39.0
Sound
Condensate
ESP
Chilled
Level
Water Pipe
Motor
Water
Power
Pipe
kW
DN
Pa
dB(A)
0.18
32
80
53
0.32
32
80
53
0.32
32
80
55
0.55
32
120
56
0.75
32
160
59
1.1
40
200
60
1.5
40
200
62
2.2
40
200
63
2.2
50
240
64
3.0
50
240
64
3.0
50
280
66
4.0
50
280
67
4.0
50
280
68
4.0
65
320
68.5
5.5
65
320
69
Power
Drive
Supply
Type
DN
25
Direct
25
Drive
25
25
25
25
25
380V
3N~
50Hz
25
25
Belt
25
Drive
25
25
25
32