Système Avancé de Filtration Membranaire MANUEL D’OPÉRATION POUR TOUS LES SYSTÈMES OI COMMERCIAUX DE LA SÉRIE VECTAPURE RSX II CE MANUEL A ÉTÉ CONÇU POUR LE PROPRIÉTAIRE DE L’ÉQUIPEMENT POUR FIN DE RÉFÉRENCE ET DE GUIDE TECHNIQUE. IL EST FORTEMENT RECOMMANDÉ DE CONTACTER LE SERVICE TECHNIQUE DE VOTRE REPRÉSENTANT WATERITE ADVENANT LE CAS D’UNE...
Félicitations! Merci d’avoir choisi un système de filtration membranaire de la série Vectapure RSX. Il vous procurera au fil des ans un service fiable s’il a été installé, opéré et maintenu correctement. Prière de lire attentivement ce manuel avant d’installer ou d’opérer ce système.
Page 3
3. Le type de membrane : les systèmes VectapureMC RSX II utilisent des membranes TFC (Thin Film Composite) de première qualité et spécialement choisies pour l’utilisation commerciale générale. Veuillez contacter votre détaillant ou Waterite pour plus d’informations au sujet des applications spéciales ou des membranes de nanofiltration.
Q: Quelle quantité d’eau le système Vectapure RSX II produit-il ? Les systèmes Vectapure RSX II sont munis de membranes à débit nominal de 350 GPJ. Le débit réel dépendra des facteurs expliqués plus haut. Dans des conditions optimales (faible taux de TSD/ TDS dans l’eau d’alimentation, eau d’alimentation à...
Page 5
√ Dureté totale : Permet de mesurer la dureté du calcium et du magnésium dans l’eau. La dureté excédant 6 grains/gallon (103 mg/l) doit être prétraitée par adoucissement. Omettre de le faire amènera une usure prématurée de la membrane par les dépôts calcaires. √...
Page 6
√ pH : La plupart des fabricants de membranes recommandent un pH d’entre 3 et 11. Nous recommandons que le système opère entre 5,5 et 9,5 pour minimiser les effets de l’eau extrêmement acide ou formant des dépôts. Les zones extrêmes de l’éventail du pH demanderont plus à votre système et elles entraîneront une corrosion prématurée sur les pièces métalliques ou des dépôts sur les composantes internes en amont de la membrane, et probablement sur la membrane elle-même.
Page 7
Tableau Sommaire Pour Prétraitement Éventail Modèles recommandé pour Effet potentiel Solution de prétraitement Waterite l’eau d’alimentation Remplacez la source d’eau Taux de production réduit RSL or Pression plus élevée pour le < 1500 ppm Passage de sel accru RSLHP système OI Série A...
Page 8
PROVENANT DES NOUVEAUX LITS DE RÉSINE PEUT ENDOMMAGER OU ENCRASSER LA SURFACE DE MEMBRANE OI. WATERITE DOES NOT RECOMMEND THE USE OF A GRANULAR/BLOCK CARBON CARTRIDGE IN THE PRE-TREATMENT FILTER HOUSINGS SUPPLIED, FOR THE PRIMARY REDUCTION OF CHLORINE. IT WILL REQUIRE REPLACEMENT TOO OFTEN, LIMIT FLOW RATES AND LIKELY LEAD TO CHLORINE BREAKTHROUGH TO THE MEMBRANE ELEMENT.
This will ensure that backpressure from the tank will not damage the membrane(s). To eliminate this problem, install the bulkhead fitting above the level switch. Consult your Waterite Commercial RO Systems Price List for information and availability on a wide variety of water system components including storage tanks, repressurization pumps, bulkheads, tube, pipe, pressure switches, fittings, UV disinfection systems and float valves.
Page 10
Pressure Gauges On/Off Switch TDS Monitor (Optional) Low Pressure Switch Inlet Solenoid Waste & Permeate Flow Meters (Optional) Membrane Housing Pre-Filter Housing DLFC Drive Pump Concentrate Valve Figure 1 Leveling Feet A Note on Fittings Your RO system has been equipped with quality push on fittings throughout. Check that all fittings are snug, as they may have loosened in transit.
Page 11
2. Remove the wrapping from the membrane element(s). Lightly lubricate the membrane brine seal and all o-rings located in the membrane housing caps with a good quality, silicone o-ring lubricant (do not use petroleum-based lubricants). Disconnect the connections on the membrane housing’s top end cap.
Page 12
4. Make sure the feed water source is a reliable one and will constantly deliver feed water between 40 psi and 80 psi maximum. Your RO system has been equipped with an low pressure shut-off, In the event that the line pressure to your RO inlet falls below 20 psi., this switch will open breaking the electrical connection.
Step 9. Complete the Electrical Connection VectaPure RSX II systems operate using a 120V 15A service and a grounded receptacle. Insure that the power source is rated to the necessary amperage (see page 8) and that the connection meets the local electrical code.
Page 14
Low Pressure Shut Off Switch Inlet Solenoid Recirculation Valve Figure 5 5. Next, begin to close the recirculation valve slowly until the operating pressure gauge registers 150 psi (10.3 bar). The system is designed to normally operate at 130 psi. At this pressure, the proper waste/production ratio is established.
This will allow you to see any developing performance trends or alert you to system changes that will require you to intervene. It will also be helpful for your dealer or Waterite technical personnel to have this information available to help troubleshoot your system, should it become necessary.
Page 16
It is the purchaser’s responsibility to immediately notify Waterite in the event that defects are detected. Seller shall not be liable for any special, incidental or consequential damages and will at its option repair or replace any defective components.
Section 6: Trouble Shooting Guide Problem Possible Cause Solution Water supply valve closed Open valve Crimped poly product line Repair or replace tube Consult dealer – may need pre- Raw water TDS too high treatment Pre-treatment cartridges plugged Replace cartridges Low or Declining Clean or replace membrane Membranes fouled...
Section 8: Feed Water Requirements RSX II 350: 2.0 USGPM minimum includes 20% safety factor RSX II 700: 3.0USGPM minimum on 1000 TDS feed water. Feed water must be available at a minimum of 40 psi and a maximum of 80 psi at the specified flow rate.
Section 10: Vectapure RSX II Performance Log WATERITE TECHNOLOGIES, INC. Unit 3 – 75 Meridian Drive, Winnipeg, Manitoba Canada R2R 2V9 204.786.1604 Fax: 204.7863.1599 waterite@waterite.com www.waterite.com Vectapure RSX II Feed Water Quality Waterite, Inc. Winnipeg, Manitoba Canada www.waterite.com...
Page 21
Owner: Contact: Installation Date: Phone # Serial # Dealer: Model # CATIONS ANIONS Barium Bromide Calcium Chloride Iron Fluoride Potassium Bicarbonate Magnesium Sulphate Manganese Nitrate Sodium Phosphate Ammonium Silica Strontium OTHER Total Alkalinity Turbidity Total Dissolved Solids Temperature Total Hardness Silt Density Index (SDI) Comments: Please fax copy to: (204) 783-1599...
Page 22
REGISTER YOUR PRODUCT ONLINE AT WATERITE.COM OR FILL OUT THE INCLUDED PRE-PAID, SELF ADDRESSED POSTCARD.
Page 23
REGISTER YOUR PRODUCT ONLINE AT WATERITE.COM OR FILL OUT THE INCLUDED PRE-PAID, SELF ADDRESSED POSTCARD.