Mounting

Figure 4

Connections

The P2 Reader should be connected to the P2 Controller using a four core cable. The
cable run should be no more than 100 metres. Data is transferred between the P2
Reader and P2 Controller through the respective X and Y terminal blocks and should
be linked X to X and Y to Y.

Inputs

Door Sensor

A door contact sensor can be fitted to DR on the Door terminal block and the negative
terminal should be wired in to the negative connection on the Reader terminal block.

Request to Exit

A normally open connection, or "push to make" connection, Request to Exit button may
also be fitted to the P2 Reader. The positive of the RQE should be wired in to RQE on
the Door terminal block and the negative should be wired in to the negative of the
Reader terminal block. The P2 reader must be fitted to Reader A on the P2 Controller
and the RQE feature enabled in Doors Express for this configuration to work

Locking Device

A small strike lock can also be fitted to the reader with a rating of no more than 100mA
by wiring in to the positive and negative Lock terminal block on the P2 Reader.