Vicon V1300X-IAF Instructions For Installation And Operation Manual

Alarm interface with relay follow

Advertisement

Quick Links

INSTRUCTIONS
FOR INSTALLATION
AND OPERATION
MODEL V1300X-IAF ALARM INTERFACE
WITH RELAY FOLLOW
The VI 300X-IAF Alarm Interface with Relay
Follow allows external alarm devices to be
connected to a Vicon NovaTM digital control
CPU and provides one dry contact output
relay per alarm input. Each Vl300X-IAF
accepts 32 alarm inputs and provides 32
relay outputs mated to the inputs. Refer to
Table 1 for a list of available models.
Units may be cascaded to accommodate
whatever maximum number of alarm inputs
can be supported by the Nova CPU. Cas-
caded units are interconnected over a par-
allel data interface using cables that are
supplied with each unit. Each V1300X-IAF
in a cascaded system is programmed with
its own unique address, which defines the
alarm input range and the relay output
range assigned to the unit.
When the V1300X-IAF senses a change in
status of one of its alarm inputs, it transmits
the information to the CPU, which an-
nounces the alarm to the operator and may
TABLE 1
MODELS AND PRODUCT CODES
Model Number ( Product Code 1 Description
I
VI 300X-IAF
4759-00
TEL: 516-952-2266; TOLL FREE: 1-600-645-9116;
INDUSTRIES INC., 69 ARKAY DRIVE, HAUPPAUGE, NY 11766
FAX 516-951-2266; UK: 44/(O) 14691566300; INFOFAX: 1-600-267-1207
also execute a preprogrammed response to
the alarm. Such responses include dis-
playing the video from the camera associ-
ated with the alarm on selected alarm
monitors, causing a camera station to carry
out a preset-position program, and dis-
playing a special alarm message on the
alarm monitors. A green LED on the front
panel of the V1300X-IAF glows steadily
during an alarm, and the unit generates a
warning tone. The tone may be disabled.
If the Vl300X-IAF is used with a VPSl300
or VPSI 344 CPU, the alarm inputs function
in the normally closed (NC) mode. If the X-
IAF is used with a VPS1444, VPS1466, or
CPU, the alarm input mode may
be programmed either normally closed (NC)
or normally open (NO). The output follower
relays always function in the normally open
(NO) mode.
Acknowledging individual alarm inputs is
performed from the Nova operator control
panel. Enabling and disabling individual
alarm inputs is done by software in the
system CPU. TheVl300X-IAF is compati-
ble with the following CPUs:
Vicon part number 8008-7913-00-00

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the V1300X-IAF and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vicon V1300X-IAF

  • Page 1 (NO). The output follower relays always function in the normally open When the V1300X-IAF senses a change in (NO) mode. status of one of its alarm inputs, it transmits the information to the CPU, which an-...
  • Page 2 Units are connected to the CPU over a par- Alarm Inputs From a Computer Alarms may be input into a Nova system allel data interface for fast response. either by direct wiring to the alarm interface In addition to the relay associated with each units or through an alarm computer or host computer.
  • Page 3 0.1 A at 30 VAC inductive. Follower Relay Rating: 0.5 A at 30 VAC resistive. Dry contacts rated at: 1 .O A at 24 VDC or Auxiliary Relay Rating: 120 VAC model: 0.75 A, 250 V, 5 X 20 mm. Fuse: 230 VAC model: 0.5 A, 250 V, 5 X 20 mm.
  • Page 4: Installation

    2.1 Unpacking and Inspection All Vicon equipment is inspected and tested the same condition in which it left the fac- before leaving the factory. It is the carrier’s tory.
  • Page 5 Connects to power outlet Data cable, 6 ft (1.8 ) Connects to next unit (X-IA, X-IAF) Connector adapter, 37 to 34 pin Allows V1300X-IAF to be cas- caded with VI 200X-IA interface Rubber feet Applied when unit is used in desk- top installation 2.2 Setting Addresses...
  • Page 6 R E A R Figure 1 Location of Cover Screws Large (main) PC Board Address 2 Address 1 0 FRONT Relay PC Board Figure 2 Location of Dip Switches X91 3 Page 6...
  • Page 7: Physical Installation

    TABLE 3 SETTING ADDRESS DIP SWITCHES 193-224 I - -256 After setting the addresses, replace the top round-headed screws are used on the cover. The five flat-head screws are used back. on the top of the unit, and the six pan- or 2.3 Physical Installation This unit may be installed in an EIA- or it may be mounted on a desktop or other...
  • Page 8 2.3.1.2 Installing the Unit In a Rack 1. Find the two rack mounting brackets (Table 2, item 2) and the four flat-head 3. Slide the unit into the rack and secure it screws (item 1) in the accessory kit. in place with four screws. These screws must be supplied by the installer, as differ- 2.
  • Page 9 + - + - + - + - + - - f - - f - + - + - + - + - + - + - + - + - + - Figure 3 Rear Panel of V1300X-IAF...
  • Page 10 Tables 4A through 4H show the system alarm number versus the VI 300X-IAF input number for 256 alarm inputs (eight cascaded V1300X-IAF units). TABLE 4A VI 300X-IAF ADDRESSED FOR INPUTS 1 - 32...
  • Page 11 TABLE 4D ADDRESSED FOR INPUTS 97 - 128 System Alarm No. X-IAF Input No. TABLE 4E ADDRESSED FOR INPUTS 129 - 160 TABLE 4F X913 Page 11...
  • Page 12: Connecting Alarm Inputs

    TABLE 4G VI 300X-IAF ADDRESSED FOR INPUTS 193 - 224 TABLE 4H VI 300X-IAF ADDRESSED FOR INPUTS 225 - 256 2.4.2 CONNECTING ALARM INPUTS Each alarm input has two wires, one of packed with the alarm device to determine which lead is ground and which is active. which is a ground.
  • Page 13: Control Cable Connection

    2.7 Control Cable Connection NOTE: Use the cable supplied with only The V1300X-IAF is compatible with all Vi- the CPU for connection to the first V?3OOX- con Nova CPUs. It may also be intermixed IAF. with VI 300X-IA alarm interface units and with the older VI 200X-IA alarm interface 1.
  • Page 14: Power Cable Connection

    CPU’s alarm interface connectors. section 2.7.2 above. 2.7.2 CONNECTING THE VI 300X-IAF TO 2.7.4 CONNECTING V1300X-IAF UNITS TO V1200X-IA UNITS ADDITIONAL VI 300X-IAFs If more than one X-IAF are cascaded to- A connector adapter is required to connect...
  • Page 15: Operation

    CPU, so that no ac- instructions to change ENABLED to DIS- knowledgment button is provided.) 3 OPERATION The V1300X-IAF has two LEDs and one Green LED: Indicates that one or more slide switch on its front panel: alarms is in progress.
  • Page 16: Shipping Instructions

    Call or write Vicon for a Return Authorization Name and address of the company returning (R.A.) at one of the locations listed below. Record the unit the name of the Vicon employee who issued the R.A. Name of the Vicon employee who issued the R.A.

Table of Contents