INSTRUCTIONS
DATA CABLE
opc- 2350lu
IMPORTANT
SAVE THESE INSTRUCTIONS! — These instructions con-
tain important safety and operating details for the data ca-
ble.
EXPLICIT DEFINITIONS
WORD
DEFINITION
CAUTION
Equipment damage may occur.
If disregarded, inconvenience only.
NOTE
No risk of personal injury, fire or elec-
tric shock.
PRECAUTIONS
CAUTION: USE ONLY INDOORS! NEVER expose the data
cable to rain, snow or any liquids.
CAUTION: NEVER let metal, wire, or other objects touch
any internal part of the connectors.
CAUTION: NEVER use other than the supplied cables. DO
NOT extend the USB cable. If a different cable or a cable
longer than 1.5 m (4.9 ft) is used, a data error may occur.
DO NOT use harsh solvents such as Benzine or alcohol
when cleaning, as they will damage the cables.
Ensure that your PC supports USB port operation by con-
firming the Universal Serial Bus controller is in the PC's De-
vice Manager.
Connect the OPC-2350LU data cable to the OPC-1637 USB
cable, then connect the USB cable to the PC's USB port di-
rectly, or to a self-powered USB hub.
Approximately 20 mA of current is required for the data ca-
ble. Insufficient current capacity of the USB port can cause
unstable operation and an error.
Icom is not responsible for the destruction, damage to, or
performance of any Icom or non-Icom equipment, if the
malfunction is because of:
• Force majeure, including, but not limited to, fires, earth-
quakes, storms, floods, lightning, other natural disas-
ters, disturbances, riots, war, or radioactive contamina-
tion.
• The use of Icom products with any equipment that is not
manufactured or approved by Icom.
Thank you for choosing this Icom product. READ
ALL INSTRUCTIONS carefully and completely be-
fore using this product.
SUPPLIED ACCESSORIES
OPC-1637
Ferrite
USB cable
USB cable
(For Android devices)
EMI filters
TM
SPECIFICATIONS
• Usable temperature range
–10˚C ~ +60˚C (+14˚F ~ +140˚F)
• Cable length (Approximately)
OPC-2350LU:
530 mm (20.9 in)
OPC-1637 USB cable:
1500 mm (4.9 ft)
USB cable (For Android
devices): 750 mm (30 in)
• Weight (Approximately)
OPC-2350LU*:
34 g (1.2 oz)
*with Ferrite EMI Filter
OPC-1637 USB cable:
49 g (1.7 oz)
USB cable (For Android
devices): 30 g (1.1 oz)
SYSTEM REQUIREMENTS
A PC with the following is required:
• Microsoft
®
Windows
®
10
32 bit/64 bit
Microsoft
®
Windows
®
8.1
32 bit/64 bit*
*Except for the "RT" version.
Microsoft
®
Windows
®
7
32 bit/64 bit
Microsoft
®
Windows Vista
®
32 bit/64 bit
• A USB 1.1 or 2.0 port
• An Internet connection is required for the USB driver in-
stallation.
An Android
device with following is required:
• Android 4.0 or later
• The RS-MS1A Android
APPLICATION needs to be in-
stalled to the Android
device before you connect the ca-
bles.
DISPOSAL
The crossed-out wheeled-bin symbol on your prod-
uct, literature, or packaging reminds you that in the
European Union, all electrical and electronic prod-
ucts, batteries, and accumulators (rechargeable
batteries) must be taken to designated collection locations
at the end of their working life. Do not dispose of these prod-
ucts as unsorted municipal waste. Dispose of them accord-
ing to the laws in your area.
CABLE CONNECTION AND USB DRIVER INSTALLATION FOR A PC
These instructions are based on using Microsoft
®
Windows
10.
q Attach the Ferrite EMI filter to the strain relief of the OPC-
1637 USB cable.
w Connect the OPC-2350LU data cable to the OPC-1637
USB cable, and then connect the USB cable to the PC's
USB port, as illustrated below.
Strain relief
OPC-1637 USB cable
to the USB port
OPC-2350LU
to the transceiver
e The driver installation status icon is displayed at the bot-
tom of the desktop screen.
CABLE CONNECTION FOR AN ANDROID
q Attach the Ferrite EMI filter to the USB cable (For An-
droid
devices).
w Connect the OPC-2350LU data cable to the USB cable
(For Android
devices), and then connect the USB cable
to the Android
device's USB port, as illustrated.
• Remove the USB cable when the Android
device is
not used. When connected, it increases the power con-
sumption of Android
device.
NOTE:
If the Android
device does not work correctly, move
away from the transceiver.
Icom, Icom Inc. and the Icom logo are registered trademarks of Icom Incorporated (Japan) in Japan, the United States, the United Kingdom, Germany, France,
Spain, Russia, Australia, New Zealand, and/or other countries.
Adobe and Reader are registered trademarks of Adobe Systems Incorporated in the United States and/or other countries.
Microsoft, Windows and Windows Vista are registered trademarks of Microsoft Corporation in the United States and/or other countries.
All other products or brands are registered trademarks or trademarks of their respective holders.
1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan
®
For your information: If the installation status icon is
clicked, the "Installing device..." dialog is displayed.
r When the installation status icon disappears, the driver
installation is completed. Restart your PC.
t After the driver installation has been completed, confirm
the driver availability and the port number.
The COM port number is used to set communication
with the cloning software. Refer to the driver installation
guide for details. You can download the Driver installa-
tion guide from Icom website.
NOTE:
• If the driver installation above is not successful, down-
load and install the driver from the Icom website. Refer
to the driver's installation guide for details.
• You need Adobe
®
®
®
Acrobat
Reader
to view the down-
loaded USB driver installation guide.
• If you do not have Adobe
®
Acrobat
®
Reader
®
it from the Adobe website.
DEVICE
USB cable
OPC-2350LU
to the transceiver
A-7176H-1G-q Printed in Japan
© 2014–2016 Icom Inc.
, download

Advertisement

loading

Summary of Contents for Icom OPC-2350LU

  • Page 1 Icom, Icom Inc. and the Icom logo are registered trademarks of Icom Incorporated (Japan) in Japan, the United States, the United Kingdom, Germany, France, at the end of their working life. Do not dispose of these prod- Spain, Russia, Australia, New Zealand, and/or other countries.
  • Page 2   ふだんは、 乾いたやわらかい布でふき、 汚れのひどいときは、 水を 使用温度範囲 : -10℃~+60℃ 本製品 (OPC-2350LU) をAndroid 端末の [USB] ポートに接 ® 含ませたやわらかい布をかたく絞ってふいてください。 ケ ー ブ ル 長 : 約530mm (OPC-2350LU) 続します。   ただし、 ケーブルの接続端子は、 絶対に水を含ませた布でふかない 約1500mm (USBケーブル (OPC-1637) ) ◎図のように付属のフェライ トコアを取り付けます。 でください。 約750mm (USBケーブル (Android ®...