Configuring the edge device as an ENDS on the EVI tunnel
Step
1.
Enter system view.
2.
Enter EVI tunnel
interface view.
3.
Enable ENDS.
4.
(Optional.) Enable
ENDP authentication.
Configuring the edge device as an ENDC on the EVI tunnel
Step
1.
Enter system view.
2.
Enter EVI tunnel
interface view.
3.
Configure the edge
device as the ENDC of
an ENDS.
4.
(Optional.) Enable
ENDP authentication.
5.
Configure the interval
at which the ENDC
updates its registration
with ENDSs.

Enabling EVI on transport-facing physical interfaces

Enable EVI on all physical interfaces that provide transport network access for EVI tunnels.
To enable EVI on an interface:
Step
1.
Enter system view.
2.
Enter Layer 2 Ethernet
interface view or Layer 3
Command
system-view
interface tunnel number
[ mode evi ]
evi neighbor-discovery
server enable
evi neighbor-discovery
authentication { cipher |
simple } string
Command
system-view
interface tunnel number
[ mode evi ]
evi neighbor-discovery
client enable server-ip
evi neighbor-discovery
authentication { cipher |
simple } string
evi neighbor-discovery
client register-interval
interval
Command
system-view
interface interface-type
interface-number
12
Remarks
N/A
N/A
By default, ENDS is disabled.
On an ENDS-enabled tunnel interface, you
can use the evi neighbor-discovery client
enable command to add one more ENDS,
and use the evi neighbor-discovery client
register-interval command to modify the
ENDC registration interval.
By default, ENDP authentication is disabled.
Remarks
N/A
N/A
By default, ENDC is disabled.
If ENDS is enabled on the EVI tunnel
interface, you can use this command to
specify only one more ENDS.
If ENDS is disabled, you can repeat this
command to specify up to two ENDSs.
ENDS address is the tunnel source address
configured on an ENDS-enabled EVI tunnel
interface.
By default, ENDP authentication is disabled.
All ENDSs and ENDCs in an EVI network
must use the same authentication key.
By default, an ENDC update its registration
with an ENDS every 15 seconds.