Introduction
Congratulations on purchasing an EIB600 Series RF RadioLINK module. These RF
modules can be easily installed in the EIB600 Series Alarms to provide you with an
RF interconnected fire warning system – when one Alarm senses fire and sounds
a warning, all the other Alarms will also sound a warning. This helps to ensure the
alarm sound will be heard throughout the property. (see Table 1 for compatibility).

Installation

1. The EIB600 Series Alarm must be installed as per the guidance in the instruction
booklet 'Battery Powered Smoke & Heat Alarms'.
2. Remove the RF module from the packaging and using the pull tag, carefully
insert into the back of the Alarm (see figure 1) - (some Alarm models may have the
RF Module already fitted).
3. Ensure that the battery is connected in the 9V Replaceable Battery Models.
House code the Alarms as follows:
4. Before fitting the Alarm to the mounting plate, press and hold the 'House Code'
switch on the rear of the RadioLINK module until the red light comes on (see
Figures 2a) and then release.
5. Twist the Alarm onto its mounting plate.
6. Similarly press and hold the House Code switch on the second Alarm until its red
light comes on and then release. Twist the Alarm onto its mounting plate. Put all
the remaining alarms into House Code mode similarly and attach to the mounting
3