During the use of device, personal data will be collected, stored and processed. To protect data, the development of Hikvision devices incorporates privacy by design principles. For example, for device with facial recognition features, biometrics data is stored in your device with encryption method;...
Page 4
DS-K3B802X Series Swing Barrier User Manual Regulatory Information FCC Information Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
Page 5
DS-K3B802X Series Swing Barrier User Manual under the EMC Directive 2014/30/EU, RE Directive 2014/53/EU,the RoHS Directive 2011/65/EU 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points.
Page 6
DS-K3B802X Series Swing Barrier User Manual Safety Instruction These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. The precaution measure is divided into Dangers and Cautions: Dangers: Neglecting any of the warnings may cause serious injury or death.
Page 7
DS-K3B802X Series Swing Barrier User Manual Do not ingest battery, Chemical Burn Hazard. ● This product contains a coin/button cell battery. If the coin/button cell battery is swallowed, it can cause severe internal burns in just 2 hours and can lead to death.
Page 8
DS-K3B802X Series Swing Barrier User Manual Do not place the device in extremely hot (refer to the specification of the device for the detailed ● operating temperature), cold, dusty or damp locations, and do not expose it to high electromagnetic radiation.
Page 9
DS-K3B802X Series Swing Barrier User Manual Available Models Product Name Model Description Swing Barrier DS-K3B802X-L Left Pedestal DS-K3B802X-M Middle Pedestal DS-K3B802X-R Right Pedestal viii...
DS-K3B802X Series Swing Barrier User Manual Contents Chapter 1 Overview ........................1 1.1 Introduction ........................... 1 1.2 Main Features ........................1 Chapter 2 System Wiring ......................3 Chapter 3 Installation ......................... 8 3.1 Disassemble before Installation ..................... 8 3.2 Install Pedestals ........................15 3.3 Install Barrier ........................
Page 11
DS-K3B802X Series Swing Barrier User Manual 5.6.7 Wiegand Wiring ......................46 5.6.8 Barrier Control Wiring ....................46 5.6.9 Alarm Output Wiring ....................48 Chapter 6 Device Settings ......................49 6.1 Set Study Mode ........................49 6.2 Pair Keyfob (Optional) ......................50 6.3 Initialize Device ........................
Page 12
DS-K3B802X Series Swing Barrier User Manual 8.4.4 Upload a Face Photo from Local PC ................72 8.4.5 Take a Photo via Client ....................73 8.4.6 Collect Face via Access Control Device ............... 74 8.4.7 Collect Fingerprint via Client ..................75 8.4.8 Collect Fingerprint via Access Control Device .............
Page 13
DS-K3B802X Series Swing Barrier User Manual 8.7.5 Configure Card Reader Authentication Mode and Schedule ........101 8.7.6 Configure First Person In ................... 103 8.7.7 Configure Anti-Passback ................... 104 8.7.8 Configure Device Parameters ..................105 8.8 Configure Linkage Actions for Access Control ..............106 8.8.1 Configure Client Actions for Access Event ..............
Page 14
DS-K3B802X Series Swing Barrier User Manual 8.11.13 View Relay Status ....................123 Appendix A. Tips for Scanning Fingerprint ................124 Appendix B. DIP Switch ......................126 B.1 DIP Switch Description ....................... 126 B.2 DIP Switch Corresponded Functions .................. 126 Appendix C. Event and Alarm Type ..................129 Appendix D.
DS-K3B802X Series Swing Barrier User Manual Chapter 1 Overview 1.1 Introduction The swing barrier with two barriers and 24 IR lights is designed to detect unauthorized entrance or exit. By adopting the swing barrier integrated with the access control system, person should authenticate to pass through the lane via swiping IC or ID card, scanning QR code, etc.
Page 16
DS-K3B802X Series Swing Barrier User Manual Bidirectional (Entering/Exiting) lane ● The barrier opening and closing speed can be configured according to the visitor flow. The barrier will be locked or stop working when people are nipped ● Anti-forced-accessing ● The barrier will be locked automatically without open-barrier signal.
DS-K3B802X Series Swing Barrier User Manual Chapter 2 System Wiring The preparation before installation and wiring. Steps 1. Draw a central line on the installation surface of the left or right pedestal. 2. Draw other parallel lines for installing the other pedestals.
Page 18
DS-K3B802X Series Swing Barrier User Manual Figure 2-1 Hole Position Diagram 4. Bury cables. Each lane buries 1 network cable and 1 high voltage cable. For details, see the system wiring diagram below.
Page 19
DS-K3B802X Series Swing Barrier User Manual Figure 2-2 System Wiring Diagram (General Wiring) Note The supplied interconnecting cable length is 5.5 m. ● The suggested inner diameter of the low voltage conduit is larger than 30 mm. ● If you want to bury both of the AC power cord and the low voltage cable at the entrance, the ●...
Page 20
DS-K3B802X Series Swing Barrier User Manual Figure 2-3 Wire Face Recognition Terminal Note The supplied interconnecting cable length is 5.5 m. ● The left pedestal and the middle pedestal should bury interconnecting cables for connecting ● the face recognition terminal.
Page 21
DS-K3B802X Series Swing Barrier User Manual The external AC power cord should be double-insulated. ● The network cable must be CAT5e or the network cable has better performance. And the ● suggested network cable length should be less than 100 m.
DS-K3B802X Series Swing Barrier User Manual Chapter 3 Installation 3.1 Disassemble before Installation Before installation, you should disassemble the pedestal and remove some screws. Before You Start Keep the disassembled components and screws. ● You should prepare the following tools to disassemble the pedestal: 1. Pedestal Key (supplied); 2.
Page 23
DS-K3B802X Series Swing Barrier User Manual Figure 3-2 M5×25 Screws 3. Remove the components along the arrow direction carefully.
Page 24
DS-K3B802X Series Swing Barrier User Manual Figure 3-3 Remove Components 4. Loosen the wing bolt (M4 × 10) at the front and back of the pedestal, and remove the front and back base covers along the arrow direction.
Page 25
DS-K3B802X Series Swing Barrier User Manual Figure 3-4 Loosen Wing Bolt Figure 3-5 Remove Base Cover You can start installing the expansion screws to secure the device on the installation surface. 5. Remove the motor bottom cover. 1) Pull or push the barrier to the closed position.
Page 26
DS-K3B802X Series Swing Barrier User Manual Figure 3-6 M4×8 Screw 3) Pull or push the barrier to the open position, and remove the motor bottom cover.
Page 27
DS-K3B802X Series Swing Barrier User Manual Figure 3-7 Remove Motor Bottom Cover Note If dissembling the middle pedestal, you should dissemble two motor bottom covers. 6. Use the Allen wretch (4 mm) to loosen the 2 screws (M5 × 12) at the front or back of the...
Page 28
DS-K3B802X Series Swing Barrier User Manual Figure 3-8 Remove Side Base Cover Note If dissembling the middle pedestal, you should dissemble two side base covers. 7. Disassemble the two protective sheets at the bottom for wiring, and you can start wiring the interconnecting cable.
DS-K3B802X Series Swing Barrier User Manual 3.2 Install Pedestals Before You Start Prepare for the installation tools, check the device and the accessories, and clear the installation base. Steps Note The device should be installed on the concrete surface or other non-flammable surfaces.
DS-K3B802X Series Swing Barrier User Manual Figure 3-11 Installation Footprint 5. After installation, assemble the components and screws back to the pedestal in reverse order (except for protective sheets). 3.3 Install Barrier Steps 1. Install the 2 nylon pipe sleeves into the barrier installation pin holes.
Page 31
DS-K3B802X Series Swing Barrier User Manual Figure 3-12 Install Nylon Pipe Sleeve 2. Install the barrier on the pipe sleeves. Figure 3-13 Install Barrier...
Page 32
DS-K3B802X Series Swing Barrier User Manual 3. Align the pipe sleeves, and install the barrier plate with 2 M6 × 12 screws. Figure 3-14 Install Barrier Panel 4. Adjust the barrier position, and make sure the barrier is in the middle. Adjust the barrier direction and make sure the barrier and the pedestal are perpendicular.
DS-K3B802X Series Swing Barrier User Manual Chapter 4 Disassemble before Maintenance Before maintaining the inner components, you should disassemble the pedestal and remove some screws. Note Keep the disassembled components and screws organized. ● You should prepare the following tools to disassemble the pedestal: 1. Pedestal Key (supplied); 2.
Page 34
DS-K3B802X Series Swing Barrier User Manual Figure 4-2 M5×25 Screws Position 3. Remove the components along the arrow direction carefully.
DS-K3B802X Series Swing Barrier User Manual Figure 4-3 Remove Components 4.2 Disassemble Motor Bottom Cover After disassembling the motor bottom cover, you can maintain the lane control board and the barrier position control board. Steps 1. Pull or push the barrier to the closed position.
Page 36
DS-K3B802X Series Swing Barrier User Manual Figure 4-4 M4×8 Screws Position 3. Pull or push the barrier to the open position, and remove the motor bottom cover.
DS-K3B802X Series Swing Barrier User Manual Figure 4-5 Remove Bottom Cover Note If dissembling the middle pedestal, you should dissemble two motor bottom covers. 4.3 Disassemble Side Base Cover After disassembling the side base cover, you can maintain the IR sending/receiving board.
Page 38
DS-K3B802X Series Swing Barrier User Manual Figure 4-6 Lock Position 2. Use the Allen wretch (3 mm) to loosen the 2 screws (M5 × 25) at the top of the device. Figure 4-7 M5×25 Screws Position 3. Remove the components along the arrow direction carefully.
Page 39
DS-K3B802X Series Swing Barrier User Manual Figure 4-8 Remove Components 4. Use the Allen wretch (3 mm) to loosen the 2 screws (M5 × 12) at the front or back of the pedestal base and remove the side base cover slowly.
DS-K3B802X Series Swing Barrier User Manual Figure 4-9 Remove Side Base Cover Note If dissembling the middle pedestal, you should dissemble two side base covers. 4.4 Disassemble Top Cover After disassembling the top cover, you can maintain the components at the top of the pedestal, the IR sending/receiving board and the IR adaptor for instance.
Page 41
DS-K3B802X Series Swing Barrier User Manual Figure 4-10 Loosen Captive Panel Screw 2. Move the front and back top covers along the arrow 1's direction for about 3 cm, and move them upwards to remove the front and back top covers.
Page 42
DS-K3B802X Series Swing Barrier User Manual Figure 4-12 Top Captive Panel Screws 5. Remove the top cover along the arrow's direction.
Page 43
DS-K3B802X Series Swing Barrier User Manual Figure 4-13 Remove Top Cover...
DS-K3B802X Series Swing Barrier User Manual Chapter 5 General Wiring 5.1 Components Introduction By default, basic components of the turnstile are connected well. The pedestals can communicate by wiring the interconnecting cables. And the turnstile supports wiring the AC electric supply for the whole system’s power supply.
Page 45
DS-K3B802X Series Swing Barrier User Manual Figure 5-1 IR Sending/Receiving Module Position Note If the turnstile contains two lanes, standing at the entrance position, the IR modules on the left pedestal are the IR sending modules. The IR modules on the right pedestal are the IR receiving modules.
DS-K3B802X Series Swing Barrier User Manual 5.2 Wiring Electric Supply Wire electric supply with the switch in the pedestal. Terminal L and terminal N are on the switch, while terminal PE should connect to a ground wire (yellow and green wire).
DS-K3B802X Series Swing Barrier User Manual To avoid people injury and device damage, when testing, the ground resistance of the ● equipotential points should not be larger than 2 Ω。 Use the device in conjunction with an UPS. ● 5.3 Wire Interconnecting Cable You should use interconnecting cables to connect the main lane board and the sub lane board for components communication.
DS-K3B802X Series Swing Barrier User Manual Figure 5-3 Connect Interconnecting Cable 5.4 Wire Network Switch Connect the network cable and the network switch. Steps 1. Open the side cover of the pedestal. Note For details, see Disassemble Side Base Cover .
DS-K3B802X Series Swing Barrier User Manual Figure 5-4 Network Switch Position 2. Lead out 12 V power supply from the main switch and connect it to the network switch's power interface. 3. Connect the network cable with the network switch.
Page 50
DS-K3B802X Series Swing Barrier User Manual Figure 5-5 Face Recognition Terminal Power Supply Wiring Position...
DS-K3B802X Series Swing Barrier User Manual 5.6 Terminal Description The lane controller contains main lane controller and sub lane controller, which controls the IR beams, motor, and other components' work. 5.6.1 Main Control Board Terminal Description The main lane control board contains power supply interface, supercapacitor interface, brake...
DS-K3B802X Series Swing Barrier User Manual Figure 5-7 Sub Control Board 5.6.3 Access Control Board Terminal Description Figure 5-8 Access Control Board...
Page 53
DS-K3B802X Series Swing Barrier User Manual Table 5-1 Access Control Board Terminal Description Access Control Board Terminal Description Power Output 1 +12 V Power Output Grounding Wiegand Card Indicator of Card Reader Control Output (Invalid Card Reader 1 Output) Indicator of Card Reader Control Output (Valid Card...
Page 54
DS-K3B802X Series Swing Barrier User Manual Access Control Board Terminal Description RS-232 G+ Connect to Card Reader RS232+ Grounding RS-232 H- Connect to Card Reader RS232- RS-232 H+ Connect to Card Reader RS232+ Power Input +24 V 24 VDC Power Input...
DS-K3B802X Series Swing Barrier User Manual Note The alarm input hardware interface is normally open by default. So only the normally open ● signal is allowed. It can be linked to the buzzer of the card reader and access controller, and the alarm relay output and open door relay output.
Page 56
DS-K3B802X Series Swing Barrier User Manual Figure 5-9 Access Control Board According to the picture above, the RS-485 serial port corresponds to UART2 and UART3. RS-232 serial port is corresponded to UART7 and UART8. Wiring Interface is corresponded to UART1, UART4, UART6, UART6, and Lane.
Page 57
Use the jumper cap to switch the serial port communication mode with the lane controller. By default, the interface is wired and it is in RS-485 communication mode. If wiring other controllers (compatible with Hikvision communication protocol), use the jumper cap to switch between RS-485 and RS-232 communication mode.
DS-K3B802X Series Swing Barrier User Manual 5.6.5 RS-485 Wiring Note There are four RS-485 interfaces, which are for connecting ID card reader, IC card reader, QR ● code scanner, fingerprint and card reader, card recycler, text screen, fingerprint reader, and face recognition terminal.
DS-K3B802X Series Swing Barrier User Manual 5.6.6 RS-232 Wiring Note There are three RS-232 interfaces (UART4, UART7, and UART8). UART7 and UART8 can connect QR code scanner, and card recycler, while UART4 can connect QR code scanner, card recycler, and face...
DS-K3B802X Series Swing Barrier User Manual 5.6.7 Wiegand Wiring Note Connect the OK/ERR/BZ if the access controller should control the LED and buzzer of the Wiegand card reader. 5.6.8 Barrier Control Wiring By default, the barrier has connected with the access control board. The lane control board can...
Page 61
DS-K3B802X Series Swing Barrier User Manual to control the third party barriers. Interface D1 controls barrier opening for entrance, while interface D2 controls barrier opening for exit. Note Use the jumper cap to switch the relay status. For details, see Barrier Control Relay Output Mode .
DS-K3B802X Series Swing Barrier User Manual 5.6.9 Alarm Output Wiring Note For details about changing the relay output status via the jumper cap, see Alarm Relay Output Mode (NO/NC) .
DS-K3B802X Series Swing Barrier User Manual Chapter 6 Device Settings After installation and wiring completed, you should set the barriers closed position (study mode) before entering the working mode. You can also set the test mode, normal mode, passing mode and memory mode, pair the keyfob,...
DS-K3B802X Series Swing Barrier User Manual 4. Power off the device. 5. Set the No.1 switches of the 8-digit DIP Switch on the main control board by referring to the following figure. 6. Power on the device again. Note For details about the DIP switch value and meaning, see DIP Switch Description.
DS-K3B802X Series Swing Barrier User Manual Note Only one turnstile can pair the keyfob. If multiple turnstiles are in the pairing mode, the ● keyfob will select only one of them to pair. For details about DIP switch value and meaning, see DIP Switch .
DS-K3B802X Series Swing Barrier User Manual Note Make sure no persons are in the lane when powering on the device. 6.4 Switch to RS-485/RS-232 Mode Take the Serial Port 4 and on the access control board as an example. If the Jumper cap's position is like the picture displayed below.
DS-K3B802X Series Swing Barrier User Manual Figure 6-3 Jumper Cap Status of RS-232 Interface 6.5 Switch Relay Output Mode (NO/NC) 6.5.1 Barrier Control Relay Output Mode The pins of the barrier control relay on the access control board is as below:...
DS-K3B802X Series Swing Barrier User Manual The jumper cap's position of barrier opening for exit (NO) is as below: The jumper cap's position of barrier closing for entrance (NC) is as below: The jumper cap's position of barrier closing for exit (NC) is as below: 6.5.2 Alarm Relay Output Mode (NO/NC)
Get the SADP software from the supplied disk or the official website http:// ● www.hikvision.com/en/ , and install the SADP according to the prompts. The device and the PC that runs the SADP tool should be within the same subnet.
DS-K3B802X Series Swing Barrier User Manual Status of the device becomes Active after successful activation. 5. Modify IP address of the device. 1) Select the device. 2) Change the device IP address to the same subnet as your computer by either modifying the IP address manually or checking Enable DHCP.
Page 71
DS-K3B802X Series Swing Barrier User Manual Caution The password strength of the device can be automatically checked. We highly recommend you change the password of your own choosing (using a minimum of 8 characters, including at least three kinds of following categories: upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product.
DS-K3B802X Series Swing Barrier User Manual Chapter 8 Client Software Configuration 8.1 Configuration Flow of Client Software Follow the flow diagram below to configure on the client software. Figure 8-1 Flow Diagram of Configuration on Client Software 8.2 Device Management...
DS-K3B802X Series Swing Barrier User Manual 8.2.1 Add Device The client also supports importing multiple devices in a batch when there are large amount of devices to be added. Add Online Device The active online devices in the same local subnet with the client software will be displayed on the Online Device area.
Page 74
DS-K3B802X Series Swing Barrier User Manual Figure 8-3 Add Single Online Device Figure 8-4 Add Multiple Online Devices 3. Enter the required information. Name...
Page 75
DS-K3B802X Series Swing Barrier User Manual Enter a descriptive name for the device. IP Address Enter the device's IP address. The IP address of the device is obtained automatically in this adding mode. Port You can customize the port number. The port number of the device is obtained automatically in this adding mode.
Page 76
DS-K3B802X Series Swing Barrier User Manual Add Multiple Detected Online Devices For detected online devices sharing the same user name and password, you can add them to the client in a batch. Before You Start Make sure the to-be-added devices are online.
Page 77
DS-K3B802X Series Swing Barrier User Manual Add Device by IP Address or Domain Name If you know the IP address or domain name of the device to add, you can add devices to the client by specifying the IP address (or domain name), user name, password, etc.
Page 78
DS-K3B802X Series Swing Barrier User Manual Note This function should be supported by the device. ● If you have enabled Certificate Verification, you should click Open Certificate Directory to ● open the default folder, and copy the certificate file exported from the device to this default directory to strengthen the security.
Page 79
DS-K3B802X Series Swing Barrier User Manual Caution The password strength of the device can be automatically checked. We highly recommend you change the password of your own choosing (using a minimum of 8 characters, including at least three kinds of following categories: upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product.
DS-K3B802X Series Swing Barrier User Manual Adding Mode Enter 0 or 1 or 2. Address Edit the address of the device. Port Enter the device port number. The default port number is 8000. User Name Enter the device user name. By default, the user name is admin.
DS-K3B802X Series Swing Barrier User Manual Note For the following operations for resetting the password, contact our technical support. Caution The password strength of the device can be automatically checked. We highly recommend you change the password of your own choosing (using a minimum of 8 characters, including at least three kinds of following categories: upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product.
DS-K3B802X Series Swing Barrier User Manual 8.3.2 Import Resources to Group You can import the device resources (such as alarm inputs/outputs, etc.) to the added group in a batch. Before You Start Add a group for managing devices. Refer to Add Group .
DS-K3B802X Series Swing Barrier User Manual 3. Click a group to show the resources added to this group. 4. Select the resource(s) and click Delete to remove the resource(s) from the group. 8.4 Person Management You can add person information to the system for further operations such as access control, video intercom, time and attendance, etc.
DS-K3B802X Series Swing Barrier User Manual 2. Select an organization in the organization list to add the person. 3. Click Add to open the adding person window. The Person ID will be generated automatically. 4. Enter the basic information including person name, gender, telephone number, email address, validity period, etc.
Page 85
DS-K3B802X Series Swing Barrier User Manual Note Enter the person's basic information first. For details about configuring person's basic information, refer to Configure Basic Information . 3. In the Credential → Card area, click +. 4. Click Settings to enter the Settings page.
DS-K3B802X Series Swing Barrier User Manual Note Currently, the supported card enrollment station models include DS-K1F100-D8, DS-K1F100- M, DS-K1F100-D8E, and DS-K1F180-D8E. Card Type This field is only available when the model is DS-K1F100-D8E or DS-K1F180-D8E. Select the card type as EM card or Mifare card according to the actual card type.
DS-K3B802X Series Swing Barrier User Manual 6. Optional: Enable Verify by Device to check whether the facial recognition device managed in the client can recognize the face in the photo. Note This function is hidden or shown according to the device capacity.
DS-K3B802X Series Swing Barrier User Manual Figure 8-7 Take a Photo via Client 7. Confirm to add the person. - Click Add to add the person and close the Add Person window. - Click Add and New to add the person and continue to add other persons.
DS-K3B802X Series Swing Barrier User Manual 2. Select an organization in the organization list to add the person and click Add. Note Enter the person's basic information first. For details about configuring person's basic information, refer to Configure Basic Information .
DS-K3B802X Series Swing Barrier User Manual 5. Select the model of the connected fingerprint recorder. Note If the fingerprint recorder is DS-K1F800-F, you can click Settings to select the COM the fingerprint recorder connects to. 6. Collect the fingerprint. 1) Click Start.
DS-K3B802X Series Swing Barrier User Manual - Click Add and New to add the person and continue to add other persons . Note Once the fingerprint is added, the fingerprint type cannot be changed. 8.4.9 Configure Access Control Information When adding a person, you can set her/his access control information, such as binding an access control group with the person, configuring PIN code, setting the person as a visitor, a blocklist person, or a super user, etc.
DS-K3B802X Series Swing Barrier User Manual Super User If the person is set as a super user, he/she will have authorization to access all the doors/ floors and will be exempted from remaining closed restrictions, all anti-passback rules, and first person authorization.
DS-K3B802X Series Swing Barrier User Manual 3) Enter the property name. 4) Click OK. 3. Set the custom information when adding a person. 1) Select an organization in the organization list to add the person and click Add. Note Enter the person's basic information first. For details about configuring person's basic information, refer to Configure Basic Information .
DS-K3B802X Series Swing Barrier User Manual Note Enter the person's basic information first. For details about configuring person's basic information, refer to Configure Basic Information . 3. In the Additional Information panel, enter the additional information of the person, including person's ID type, ID No., job title, etc., according to actual needs.
DS-K3B802X Series Swing Barrier User Manual 8.4.15 Import Person Pictures After importing face pictures for the added persons to the client, the persons in the pictures can be identified by an added face recognition terminal. You can either import person pictures one by one, or import multiple pictures at a time according to your need.
DS-K3B802X Series Swing Barrier User Manual 8.4.17 Export Person Pictures You can export face picture file of the added persons and save in your PC. Before You Start Make sure you have added persons and their face pictures to an organization.
DS-K3B802X Series Swing Barrier User Manual 5. Click Import to start importing the person information to the client. Note Up to 2,000 persons and 5,000 cards can be imported. The person information, including person details, person's fingerprint information (if configured), and the linked cards (if configured), will be imported to the selected organization.
DS-K3B802X Series Swing Barrier User Manual The person(s) in the list will be issued with card(s). 8.4.21 Report Card Loss If the person lost his/her card, you can report the card loss so that the card's related access authorization will be inactive.
DS-K3B802X Series Swing Barrier User Manual This field is only available when the model is DS-K1F100-D8E or DS-K1F180-D8E. Select the card type as EM card or IC card according to the actual card type. Serial Port It is only available when the model is DS-K1F100-M.
DS-K3B802X Series Swing Barrier User Manual 4. Optional: Enter the descriptions or some notifications of this holiday in the Remark box. 5. Add a holiday period to the holiday list and configure the holiday duration. Note Up to 16 holiday periods can be added to one holiday.
DS-K3B802X Series Swing Barrier User Manual The access authorization is valid in each day of the week and it has no holiday. All-Day Denied The access authorization is invalid in each day of the week and it has no holiday.
Page 102
DS-K3B802X Series Swing Barrier User Manual Before You Start Add person to the client. ● Add access control device to the client and group access points. For details, refer to Group ● Management . Add template. ● Steps When the access group settings are changed, you need to apply the access groups to the devices again to take effect.
Page 103
DS-K3B802X Series Swing Barrier User Manual Figure 8-9 Display the Selected Person(s) and Access Point(s) 8. After adding the access groups, you need to apply them to the access control device to take effect. 1) Select the access group(s) to apply to the access control device.
DS-K3B802X Series Swing Barrier User Manual Note If you change the persons' access information or other related information, you will view the promptAccess Group to Be Applied on the right corner of the client. You can click the prompt to apply the changed data to the device. You can select either Apply Now or Apply Later.
Page 105
DS-K3B802X Series Swing Barrier User Manual Steps 1. Click Access Control → Advanced Function → Device Parameter . Note If you can find Device Parameter in the Advanced Function list, Hover the cursor on the Advanced Function, and then Click to select the Device Parameter to be displayed.
Page 106
DS-K3B802X Series Swing Barrier User Manual 2. Select an access control device on the left panel, and then click to show the doors or floors of the selected device. 3. Select a door or floor to show its parameters on the right page.
Page 107
DS-K3B802X Series Swing Barrier User Manual Note The door's status duration settings will be copied to the selected door(s) as well. Configure Parameters for Card Reader After adding the access control device, you can configure its card reader parameters. Steps 1.
Page 108
DS-K3B802X Series Swing Barrier User Manual When you inputting the password on the card reader, if the interval between pressing two digits is larger than the set value, the digits you pressed before will be cleared automatically. Tampering Detection Enable the anti-tamper detection for the card reader.
Page 109
DS-K3B802X Series Swing Barrier User Manual Steps 1. Click Access Control → Advanced Function → Device Parameter to enter Parameter Settings page. 2. In the device list on the left, select a lane controller and you can edit the lane controller's parameters on the right.
DS-K3B802X Series Swing Barrier User Manual Lane Length The width of the lane. You can set the lane width. Note The lane width will affect the device working. Set a correct lane width or the barrier may not open. Do Not Open Barrier When Lane is Not Clear If there is someone or something in the lane, the gate will not open even if the credential is authenticated.
DS-K3B802X Series Swing Barrier User Manual Copy to Whole Select one duration on the time bar, click Copy to Whole Week to copy all Week the duration settings on this time bar to other week days. Delete Selected Select one duration on the time bar, click Delete Selected to delete this duration.
Page 112
DS-K3B802X Series Swing Barrier User Manual 3. Add a person/card group for the access control device. 1) Click Add on the right panel. 2) Create a name for the group as desired. 3) Specify the start time and end time of the effective period for the person/card group.
Page 113
DS-K3B802X Series Swing Barrier User Manual Figure 8-11 Remotely Open Door Note You can check Offline Authentication to enable the super password authentication when the access control device is disconnected with the client. Local Authentication and Super Password Authentication by the access control device and by the super password.
DS-K3B802X Series Swing Barrier User Manual 8.7.4 Configure Custom Wiegand Rule Based on the knowledge of uploading rule for the third party Wiegand, you can set multiple customized Wiegand rules to communicate between the device and the third party card readers.
DS-K3B802X Series Swing Barrier User Manual Figure 8-12 Set Output Transformation Rule 2) Select rules on the left list. The selected rules will be added to the right list. 3) Optional: Drag the rules to change the rule order. 4) Click OK.
Page 116
DS-K3B802X Series Swing Barrier User Manual Figure 8-13 Select Card Reader Authentication Mode Note PIN refers to the PIN code set to open the door. Refer to Configure Access Control Information . 2) Check the modes in the Available Mode list and they will be added to the selected modes list.
DS-K3B802X Series Swing Barrier User Manual Figure 8-14 Set Authentication Modes for Card Readers 6. Optional: Select a configured day and click Copy to Week to copy the same settings to the whole week. 7. Optional: Click Copy to to copy the settings to other card readers.
DS-K3B802X Series Swing Barrier User Manual The door remains open for the configured time duration after the first person is authorized until the remain open duration ends. If you select this mode, you should set the remain open duration. Note The remain open duration should be between 0 and 1440 minutes.
DS-K3B802X Series Swing Barrier User Manual 2. Select an access control device on the left panel. 3. Select a card reader as the beginning of the path in the First Card Reader field. 4. Click of the selected first card reader in the Card Reader Afterward column to open the select card reader dialog.
DS-K3B802X Series Swing Barrier User Manual The configured parameters will be applied to the device automatically. ● When you change the working mode or connection mode, the device will reboot ● automatically. Enable M1 Card Encryption M1 card encryption can improve the security level of authentication.
DS-K3B802X Series Swing Barrier User Manual Before You Start Add access control device to the client. Steps 1. Click Event Configuration → Access Control Event . The added access control devices will display in the device list. 2. Select a resource (including device, alarm input, door, and card reader) from the device list.
DS-K3B802X Series Swing Barrier User Manual 2. Select the access control device from the list on the left. 3. Click Add button to add a new linkage. 4. Select the event source as Event Linkage. 5. select the event type and detailed event to set the linkage.
DS-K3B802X Series Swing Barrier User Manual An event-related picture will be captured when the selected event happens. Note The device should support recording. Alarm Output The alarm output will be triggered for notification. Alarm Input Arm or disarm the alarm input.
DS-K3B802X Series Swing Barrier User Manual 8.9.1 Control Door Status You can control the status for the door(s), including unlock door, locking door, remaining the door unlock, remaining the door locked, remain all unlocked, etc. Before You Start Add person and assign access authorization to designed person, and person will have the access ●...
DS-K3B802X Series Swing Barrier User Manual All doors in the group will be closed and locked. No person can access the doors even if he/she has the authorized credentials, except the super users. Capture Capture a picture manually. Note The Capture button is available when the device supports capture function. The picture is saved in the PC running the client.
DS-K3B802X Series Swing Barrier User Manual Note You can right click the column name of access event table to show or hide the column according to actual needs. 2. Optional: Select an access point group from the drop-down list in the upper-right corner to show the real time access records of the selected group.
DS-K3B802X Series Swing Barrier User Manual Steps 1. Click → Tool → Device Arming Control to open Device Arming Control page. All the added devices appear on this page. 2. Optional: If there are to many devices, enter the key words in Filter filed to filter the device(s) you want.
Page 128
DS-K3B802X Series Swing Barrier User Manual Steps 1. Click Event Center → Real-time Event to enter the real-time event page and you can view the real-time events received by the client. Event Time For encoding device, event time is the client time when it receives the event. For other device types, event time is the time when the event is triggered.
DS-K3B802X Series Swing Barrier User Manual Enlarge Video or Double click the video image to view video in a larger window. ● Picture Put the cursor on the picture, and click to view picture in a ● larger window. Download Captured...
Page 130
DS-K3B802X Series Swing Barrier User Manual Note You can enter a key word (supports fuzzy search) in the search box to search the target event type(s). Status The handling status of the event. Search by Keyword Enter a key word (supports fuzzy search) to quickly search the target historical event(s). For example, you can enter a person's name to search the events related with this person.
DS-K3B802X Series Swing Barrier User Manual Export Event Click Export to export the event log or event pictures to the local PC in Information CSV/Excel file. You can set the saving path manually. Download Hover the cursor on the captured picture, and click the download icon on Captured Picture the lower right corner of the picture to download it to the local PC.
DS-K3B802X Series Swing Barrier User Manual 8.11.4 Set System Maintenance You can reboot the device remotely, restore the device to default settings, etc. Steps 1. Click Maintenance and Management → Device Management → Device to enter the device list. 2. Click to enter the remote configuration page.
DS-K3B802X Series Swing Barrier User Manual 8.11.6 Manage Keyfob User Steps 1. Click Maintenance and Management → Device Management → Device to enter the device list. 2. Click to enter the remote configuration page. 3. Click System → User → Keyfob User .
DS-K3B802X Series Swing Barrier User Manual 2. Click to enter the remote configuration page. 3. Click System → Lane Settings . 4. Set the lane parameters. Door Closing Delay Time Set the delayed time duration when barrier is closing. The barrier will be closed after the configured delayed time.
DS-K3B802X Series Swing Barrier User Manual Select the text font size in the screen. Screen Orientation Select the text orientation on the screen. Line Space Set the space between two lines. Column Spacing Set the space between two columns. Initial Position Set the first character's position displayed on the screen.
DS-K3B802X Series Swing Barrier User Manual The device will count the people who passing through the device depending on the detection result. By Authentication Number The device will count the people who authenticating on the device. The failed authentication will also count as once.
DS-K3B802X Series Swing Barrier User Manual Note The imported audio file should be in MEM format. ● For details about converting other format of the audio file to MEM format, see the audio ● conversion manual. If you use the third part software to create or edit an audio file, the volume of the audio file ●...
DS-K3B802X Series Swing Barrier User Manual Appendix A. Tips for Scanning Fingerprint Recommended Finger Forefinger, middle finger or the third finger. Correct Scanning The figure displayed below is the correct way to scan your finger: You should press your finger on the scanner horizontally. The center of your scanned finger should align with the scanner center.
Page 139
DS-K3B802X Series Swing Barrier User Manual Environment The scanner should avoid direct sun light, high temperature, humid conditions and rain. When it is dry, the scanner may not recognize your fingerprint successfully. You can blow your finger and scan again.
DS-K3B802X Series Swing Barrier User Manual Appendix B. DIP Switch B.1 DIP Switch Description The DIP switch is on the main lane control board. No.1 to No 8 is from the low bit to the high bit. When the switch is towards ON, it means the switch is enabled, otherwise, the switch is off. If you set the DIP switch like the figure displayed below, its binary value is 00001100, and its decimal value is 12.
Page 141
DS-K3B802X Series Swing Barrier User Manual Device Mode Function Decimal Value DIP Switch Address Diagram Memory Mode Enable Memory Mode Disable Memory Mode Keyfob Paring Disable Keyfob Mode Paring Mode Enable Keyfob Paring Mode 5 to 8 Passing Mode Controlled Bi-...
Page 142
DS-K3B802X Series Swing Barrier User Manual Device Mode Function Decimal Value DIP Switch Address Diagram Prohibit Entrance and Controlled Exit Prohibit Entrance and Free Exit...
DS-K3B802X Series Swing Barrier User Manual Appendix C. Event and Alarm Type Event Alarm Type Tailgating Visual and Audible Reverse Passing Visual and Audible Force Accessing None Climb over Barrier Visual and Audible Overstay Visual and Audible Passing Timeout None...
DS-K3B802X Series Swing Barrier User Manual Appendix D. Table of Audio Index Related Content Index Content Authenticated. Card No. does not exist. Card No. and fingerprint mismatch. Climbing over the barrier. Reverse passing. Passing timeout. Intrusion. Force accessing. Tailgating. No permissions.
DS-K3B802X Series Swing Barrier User Manual Appendix E. Error Code Description The swing barrier will display the error code on the seven-segment display if error occurred. Refer to the table below to find the description of each number. Error Reason...
Device Command Scan the following QR code to get the device common serial port commands. Note that the command list contains all commonly used serial ports commands for all Hikvision access control and video intercom devices. Figure F-2 Device Command...
Need help?
Do you have a question about the DS-K3B802X Series and is the answer not in the manual?
Questions and answers