17) Adjusting the needle bar height
Set the feed adjustment dials to the minimum settings. Then adjust so that the distance from the setting surface
of the needle plate 2 to the end of the needle bar 1 is 18.5mm
when the needle bar 1 is at its lowest position.
(1) Remove the face plate.
(2) Set the feed adjustment dials to "0".
(3) Turn the pulley to set the needle bar 1 to its lowest
position.
(4) Loosen the screw 3 and then move the needle bar 1 up or
down to adjust so that the distance from the setting surface of
the needle plate 2 to the end of the needle bar 1 is 18.5 mm.
(5) Tighten the screw 3, install the face plate.
18) Adjusting the gap between the needle and the
rotary hook tip
The gap between the needle and the rotary hook tip 1 is 0.1 mm.
Set the rotary hook tip at the level of the middle of the needle. Then
adjusting the gap as follow:
(1) Loosen the screws 2 and 5 (see the picture of below).
(2) Set the hook base 6 to the fit position.
(3) Rotate the adjusting plate 3, let the hook base 6 depend on the bed plate
4.
(4) Tighten the screws 2 and 5.
19) Adjusting of the needle and the hook timing
(1) Set the stitch length to "0".
(2) Remove the needle plate.
From the library of: Superior Sewing Machine & Supply LLC
— 10 —