Page 1
MODEL: MSVSS OPERATING INSTRUCTIONS, INSTALLATION & MAINTENANCE MANUAL INCLUDING SPARE PARTS LIST Mody Pumps Inc. 2166 Zeus Court Bakersfield, CA 93308 Tel.: (661) 392-7600 FAX.: (661) 392-7601 EMAIL: sales@modypump.com http://www.modypump.com with of the Contractors Pump Bureau.
Page 2
Mody Pumps Inc.: 2166 Zeus Court, Bakersfield, CA 93308 Tel.: (661) 392-7600 Fax: (661) 392-7601...
Page 3
INTRODUCTION The “Mody” motor driven portable submersible pumps have been developed due to a long felt need of having a truly maintenance free pump-set for various applications. The pump is a lightweight, compact unit that can be used in most sea-craft and difficult land installations.
GENERAL INFORMATION MODY NON-CLOG VORTEX SS SLUDGE PUMPS have basically been designed and manufactured with the highest quality components and used as heavy-duty dewatering/wastewater units to pump out flooded installations or any other conditions that need removal of solids laden unwanted fluids. The pumps are capable of handling water contaminated with oil as well as stringy solids normally associated with raw and sewage water with pH levels ranging from 3 - 10.
Page 5
1. Receiving: Pump should be inspected for damage upon receiving. If damage has occurred, contact Mody Pumps Inc. or your authorized distributor to file a claim immediately. 2. Check Insulation and Phase Ohm Resistance: Before operating pump, ensure the voltage and phase information stamped on Name Plate matches with the available power.
3. Inspection of thermal and moisture sensors if provided: Identify control cables. Mody Pumps provides a reference such as color-coded labels or sticker on the cable. a. Probe Sensor. Normally open Using a multimeter and setting it on the Ohm resistance mode, connect meter terminals to wires (Probe) and Green (Ground) and check for ohm resistance.
d. Discharge/ Suction: Ensure discharge connection is correctly and securely fitted. Ensure delivery hose is free from kinks and sharp bends. Pump should have strainer affixed at all times. Inspect and clean strainer periodically for maximum efficiency and performance. e. Float system: if applicable Attach “ON”...
Page 8
Seals: Condition of seals shall be checked every 2500 hrs. of operation by ascertaining the condition of oil in the seal chamber. Milky white oil indicates the presence of water in the oil chamber and a pressure check needs to be performed. Pressure test: The pressure test must be performed to ensure the seal faces are properly installed during assembly.
Page 9
SERVICE CENTERS: For the location of the nearest Factory Authorized Mody Pumps Service Center, check with your Local Mody Representative in your Country or State/Province or contact Mody Pumps Inc. We are located at 2166 Zeus Court Bakersfield, CA 93308 USA Tel.: +1 661-392-7600 FAX.: +1 661-392-7601.
Mody Pumps, Inc. or its Authorized Service Center. A warranty-claimed pump can only be received at Mody Pumps, Inc. or its Authorized Service Center if it is returned with a valid RMA from Mody Pumps, Inc.