Electrical connection

All work on the electrical
connection must be carried out by
the Miele Professional Service
Department, a Miele authorised
technician or a qualified electrician.
- The electrical installation must
comply with current local and
national safety regulations.
- The connection to the power supply
must comply with national
regulations (plug and socket must be
accessible for service and
maintenance work after the machine
has been installed). An electrical
safety test must be carried out after
installation and after any service
work.
- If the dishwasher is hard wired to the
power supply, connection should be
made via a mains switch with all-pole
isolation. The mains switch must
ensure a 3 mm gap between all open
contacts, and must be able to be
locked in the off position. The means
for disconnection must be
incorporated in the fixed wiring in
accordance with the wiring rules.
- Equipotential bonding should be
carried out if required.
- If replacing the mains connection
cable, use only original Miele
replacement parts or a suitable cable
with core cable ends.
- For technical data see data plate or
wiring diagram supplied.
The machine must only be operated
with the voltage, frequency and fusing
shown on the data plate.
This machine can be converted to a
different type of power supply in
accordance with the conversion
diagram and wiring diagram supplied.
Converting the machine to a different
type of power supply can lead to
longer programme durations,
resulting in increased energy
consumption in some programmes.
The values declared on the label will
only be achieved if the machine
remains in the state in which it was
delivered.
The data plates are located at the back
of the dishwasher and along the right
edge of the open door.
The wiring diagram is supplied with
the machine.
The conversion diagram is attached to
the electrical connection plinth panel
behind the plinth cover.
Equipotential bonding connection
There is a screw connection point
marked  at the back of the appliance,
to which additional equipotential
bonding can be connected.