MONITORING
This menu pages allows you to apply the needed settings to the alarms. The following submenus
are available:
•
Alarm Notification – you can enable/disable the available notification types.
Alarms – gives you full control to all alarms that could be generated.
•
•
GP Outputs – from here you can assign function to the General Purpose Outputs.
Alarms is a special parameter type with its own dialog editor. Each alarm parameter is composed
of the following sub-parameters:
Low threshold – the lower alarm limit of the measured signal. If the value stays below this
•
limit for predefined time "low alarm" event will be generated;
High threshold – the higher alarm limit of the measured signal. If the value stays above this
•
limit for predefined time "high alarm" event will be generated;
Trigger time – waiting time before a "low alarm" or "high alarm" event is generated;
•
•
Release time – waiting time before an "Idle alarm" event is generated;
•
Set of notification channels – In case of alarm, maintenance staff will be immediately alerted
via E-mail, SNMP or GPO, which allows technicians to restore the normal service as soon
as possible.