Model VZN-441 & VZN-441V-TS
Original Instructions
www.antunes.com
Scan with mobile device or enter URL
for product and service information.
owner's manual
Manufacturing Numbers:
9700741 & 9700751
System Tested and Certified by NSF
International against NSF/ANSI
Standard 42 and 53 for the reduction of:
Standard No. 42: Aesthetic Effects
Nominal Particulate Reduction Class I
Standard No. 53: Health Effects
Cyst Reduction & Turbidity Reduction as
verified and substantiated by test data.
System Tested and Certified
against NSF/ANSI Standard 372
for lead-free compliance
®
A.J. Antunes & Co.
VZN-441V
http://tiny.cc/ajaVZN441V
P/N 1011079 Rev. L 07/19

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VZN-441 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Antunes VZN-441

  • Page 1 A.J. Antunes & Co. VZN-441V Scan with mobile device or enter URL for product and service information. http://tiny.cc/ajaVZN441V Water Filtration System Model VZN-441 & VZN-441V-TS owner’s manual Manufacturing Numbers: 9700741 & 9700751 System Tested and Certified by NSF International against NSF/ANSI Standard 42 and 53 for the reduction of: Standard No.
  • Page 2: Table Of Contents

    VZN V SERIES TABLE OF CONTENTS Owner Information ...............2 System Inlet Connection ..........12 General................2 Filtered Water Permeate Outlet Connection ....12 Warranty Information ............2 Inlet Water Plumbing ............12 Service/Technical Assistance ..........3 Installing a Bypass ............13 Important Safety Information ..........4 Starting the Controller ............
  • Page 3: Service/Technical Assistance

    Serial No.: Mfg. No.: IMPORTANT Antunes reserves the right to change specifications and product design without notice. Such revisions do NOT entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment. P/N 1011079 Rev. L 07/19...
  • Page 4: Important Safety Information

    Do NOT modify the power supply cord plug. If it • This equipment should be serviced by qualified person- does not fit the outlet, have a proper outlet installed nel only. Contact Antunes for repair. by a qualified electrician. • Do NOT immerse cord or plug in water.
  • Page 5 VZN V SERIES IMPORTANT SAFETY INFORMATION (continued) Protect from becoming dry CAUTION If the membrane dries out, irreversible damage to the Ultra This equipment is to be installed to comply with the Filter membrane may result. Protect the filter from becoming basic plumbing code of the Building Officials and Code dry by keeping it wet and sealed at all times.
  • Page 6: Specifications

    VZN V SERIES SPECIFICATIONS Electrical Ratings Dimensions Model & Volts Watts Amps Hertz VZN-441V VZN-441V-T5 Mfg. No. VZN-441V 100–240 50/60 9700741 VZN-441V-T5 100–240 50/60 9700751 NOTE: Includes plug adaptors for US, Europe, Australia, and UK. Replacement Cartridges Replacement Part Number VZN-441V L-440 Ultra Filter 7000412...
  • Page 7: Performance Data Sheet

    VZN V SERIES PERFORMANCE DATA SHEET Performance Claims for Percent Reduction Filter Cartridge Capacities Substance Influent Reduction Minimum Maximum Operating Pressure 100 psig (690 kPa) Challenge Requirement Maximum Operating Temperature 100°F (38°C) Concentration Reduction Minimum Operating Temperature 40°F (4°C) cyst minimum 99.95% 99.95%...
  • Page 8: Operation

    VZN V SERIES OPERATION Overview The VZN system operates in two modes: System Flush • Normal Operation Mode Solenoid Valve (Automatic) • Flush Mode Rinse Ball Valve During Normal Operation Mode, water enters the Inlet and (Manual) flows through the Ultra Filter before exiting the Permeate Outlet as usable product water.
  • Page 9: Installation

    Rinse Outlet 3/4" (Garden Hose or 3/4" ID Hose) obtaining warranty coverage. NOTE: If any parts are damaged, contact Antunes When making a plumbing connection to the system, use a IMMEDIATELY at 1-800-253-2991 (toll free in the U.S. and back-up wrench on the supporting plumbing. Always use a Canada) or 1-630-784-1000.
  • Page 10: Mounting The System

    VZN V SERIES INSTALLATION (continued) CAUTION Back Plate The system is (holes along bottom designed to hang from Due to its weight and size, the VZN system MUST be for additional the Mounting Bracket. mounted with the provided Mounting Bracket. Read mounting stability) the Mounting the System section before attempting to mount the VZN system.
  • Page 11: Drain Valve Connection

    VZN V SERIES INSTALLATION (continued) Drain Valve Connection The drain is for flushing particle buildup out of the Example Drain Valve system during self cleaning. Connection 1. Cut a length of tubing (not supplied) so it reaches the Secure Hose drain from the Drain Valve.
  • Page 12: Rinse Valve Connection

    VZN V SERIES INSTALLATION (continued) Rinse Valve Connection 1. Obtain a length of 3/4” garden hose long enough to reach from the Rinse Valve to the drain. 2. Install a gasket in the end of the hose (non-drain end). 3. Connect the hose to the Rinse Valve fitting. Use a back- up wrench on the fitting if required (Figure 5).
  • Page 13: Installing A Bypass

    VZN V SERIES INSTALLATION (continued) Rinsing the Ultra Filter Cartridge The Ultra Filter Cartridge comes pre-installed in the VZN system. The Ultra Filter Cartridge must be rinsed before the system is used to remove any air and protective solution. NOTE: Ultra Filter Cartridge must be rinsed to drain Outlet Ball Valve before use.
  • Page 14: Sanitizing The System And Lines

    VZN V SERIES INSTALLATION (continued) Sanitizing the System and Lines Rinsing the Carbon Element and TAC Cartridge The plumbing must be sanitized to eliminate possible contam- The Carbon Element and TAC Cartridge MUST be rinsed ination that may have occurred during the installation process. before using the system the first time and immediately after the Carbon Element or TAC Cartridge have been replaced.
  • Page 15: Maintenance

    VZN V SERIES MAINTENANCE Replacing the Ultra Filter Cartridge NOTE: Always install new Carbon Element and new Snap Ring TAC Cartridge Element after replacing the Ultra Filter Cartridge. 1. Turn off water to the system by closing the Inlet Ball End Cap Valve and Outlet Ball Valve.
  • Page 16: Rinsing And Replacing The Carbon Element

    VZN V SERIES MAINTENANCE (continued) Rinsing and Replacing the Carbon Element RED Pressure O-Ring NOTE: Remove the TAC Cartridge Element, if present, Relief Button and re-attach the TAC Housing before proceeding. Carbon Element 1. Turn off the water to the system by closing the Inlet Ball Head Valve and Outlet Ball Valve.
  • Page 17: Rinsing And Replacing The Tac Cartridge (Vzn-441V-T5 Only)

    VZN V SERIES MAINTENANCE (continued) Rinsing and Replacing the TAC Cartridge (VZN-441V-T5 ONLY) NOTE: Do not perform this procedure with a new Carbon Element installed 1. Turn off water to the system by closing the Inlet Ball Valve and then close the Outlet Ball Valve. 2.
  • Page 18: Changing The Interval Setting

    VZN V SERIES MAINTENANCE (continued) Changing the Interval Setting Resetting the Timer Program During the normal operation, the system will flush accord- CAUTION ing to the set interval. It is possible the system will flush at a Changing the flush interval may cause the Ultra Filter time of high water use.
  • Page 19: Troubleshooting

    VZN V SERIES TROUBLESHOOTING Problem Possible Cause Corrective Action The power cord is not plugged into the Plug power cord into the appropriate outlet. appropriate outlet or control box. The unit is plugged into a switched Plug the power cord into an unswitched outlet. Unit does not have power.
  • Page 20: Replacement Parts

    VZN V SERIES REPLACEMENT PARTS VZN-441V Systems P/N 1011079 Rev. L 07/19 ®...
  • Page 21 VZN V SERIES REPLACEMENT PARTS (continued) VZN-441V-T5 Systems P/N 1011079 Rev. L 07/19 ®...
  • Page 22 VZN V SERIES REPLACEMENT PARTS (continued) Replacement Parts can be purchased from an authorized dealer. Contact Antunes at 1-630-754-1000 or toll free in the United States at 1-800-253-2991. VZN-441V Systems Item Part Description Qty. Item Part Description Qty. 0505886 VZN Back Plate 20 2010204 Tubing, Bent 180°...
  • Page 23: Notes

    VZN V SERIES NOTES P/N 1011079 Rev. L 07/19 ®...
  • Page 24: Limited Warranty

    Equipment. 2. Antunes reserves the right to make changes in design or add any improvements on any product. The right is always reserved to modify equipment because of factors beyond our control and government regulations.