Advertisement

Quick Links

Water Filtration System
Model VZN-441VA
owner's manual
Manufacturing Numbers:
9700776
Cartridge Tested and Certified by NSF
International against NSF/ANSI Standard
42 and 53 for the reduction of:
Standard No. 42: Aesthetic Effects
Nominal Particulate Reduction Class I
Standard No. 53: Health Effects
Cyst Reduction & Turbidity Reduction
as verified and substantiated by test data.
www.antunes.com
P/N 1011202 Rev. C 11/16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VZN-441VA and is the answer not in the manual?

Questions and answers

Summary of Contents for Antunes VZN-441VA

  • Page 1 Water Filtration System Model VZN-441VA owner’s manual Manufacturing Numbers: 9700776 Cartridge Tested and Certified by NSF International against NSF/ANSI Standard 42 and 53 for the reduction of: Standard No. 42: Aesthetic Effects Nominal Particulate Reduction Class I Standard No. 53: Health Effects Cyst Reduction &...
  • Page 2: Table Of Contents

    All information contained installation or operation of your system, in this manual should be read prior to Service/Technical contact A.J. Antunes & Co. at 1-630-784- installing and operating the system. Assistance ..........2 1000, or toll free in the United States at...
  • Page 3: Important Safety Information

    Con- (outlet pressure 60 psig - 100 or other tools. Cutting or nicking a plastic tact A.J. Antunes & Co. for repair. psig max (414 kPa - 690 kPa part can weaken it and cause a leak. Do NOT Do NOT immerse cord max).
  • Page 4: Specifications

    SPECIFICATIONS Model & Width Depth Height Mfg. No. VZN-441VA 24" 10 1/8" 49 5/16" 9700776 (61 cm) (26 cm) (125 cm) Electrical Cord & Plug Configurations Electrical Ratings Model & Kit Model Volts Watts Amps Hertz Description Configuration Mfg. No.
  • Page 5: Performance Data Sheet

    Range 3-10 MWCO 100 kD Rated Service Flow: 13 gpm (49 l/m) VZN-441VA Cartridge Tested and Certified by NSF International against NSF/ANSI Standard 42 and 53 for the reduc- tion of: Standard No. 42: Aesthetic Effects Nominal Particulate Reduction Class I Standard No.
  • Page 6: Installation

    Drain 3/4” FNPT NOTE: If any parts are damaged, contact 3/4” (Garden Hose or 3/4” A.J. Antunes & Co. IMMEDIATELY Rinse Outlet ID Hose) at 1-800-253-2991 (toll free in the U.S. and Canada) or 1-630-784- 1000. When making a plumbing connection to the system, use a back-up wrench on the supporting plumbing.
  • Page 7 Secure the bottom portion of the CAUTION VZN system to the wall using the Due to its weight and size, the VZN system holes provided. Make sure the MUST be mounted with the provided Mount- mounting hardware secures the ing Bracket. Read the Mounting the System system into wall studs or use the ap- section before attempting to mount the VZN propriate mounting hardware.
  • Page 8 Drain Valve Connection Example Drain Valve The drain is for flushing particle buildup out Connection of the system during self cleaning. Secure Hose Cut a length of tubing (not supplied) with Worm Clamp so it reaches the drain from the Drain Valve.
  • Page 9 Rinse Valve Connection Obtain a length of 3/4” garden hose long enough to reach from the Rinse Valve to the drain. Install a gasket in the end of the hose (non-drain end). Connect the hose to the Rinse Valve fitting. Use a back-up wrench on the Rinse Valve Connection fitting if required (Figure 5).
  • Page 10 Installing a Bypass Rinsing the Ultra Filter Cartridge After 15 minutes, close the Rinse Ball Valve and allow the system to sit for It is recommended that an optional bypass The Ultra Filter Cartridge comes pre-in- 15 minutes without any water flow be installed to help with replacing cartridg- stalled in the VZN system.
  • Page 11 Sanitizing the System and Lines 13. Allow water to flow through the system until the The plumbing must be sanitized to elimi- presence of sanitizer is gone. nate possible contamination that may have 14. Open all other faucets and taps in occurred during the installation process.
  • Page 12: Operation

    OPERATION Manual Flushing A manual flush can be activated at any Overview time by pressing the FLUSH button on the Universal Pulse Controller. The VZN system operates in two modes: Normal Operation Mode When the FLUSH button is pressed, the Flush LED on the controller flashes and the Flush Mode Drain Valve opens for 10 seconds.
  • Page 13: Maintenance

    MAINTENANCE 11. Install the End Cap O-ring on the End NOTE: Make sure the fitting is complete- Cap and insert the Large End Cap ly inserted onto the tubing past the O-ring. A loose connection Replacing the Ultra Filter into the end of the new cartridge. results in leaking at the point of Cartridge 12.
  • Page 14 Rinsing and Replacing the Carbon System Sanitization NOTE: Do NOT consume the water used for rinsing the Carbon Element. Element The system and downstream plumbing 14. When the rinsing is complete, close should be sanitized every six months. When Turn off the water to the system by the Rinse Ball Valve and open the necessary, follow the procedure in Sanitiz- closing the Inlet Ball Valve and Outlet...
  • Page 15 Changing the Interval Setting Resetting the Timer Program CAUTION During the normal operation, the system Air pre-charge should only be checked CAUTION will flush according to the set interval. It is and adjusted under zero system pres- Changing the flush interval may cause possible the system will flush at a time of sure.
  • Page 16: Troubleshooting

    TROUBLESHOOTING Problem Possible Cause Corrective Action The power cord is not plugged into the appropriate outlet Plug power cord into the appropriate outlet. or control box. The unit is plugged into a switched Unit does not have power. Plug the power cord into an unswitched outlet. electrical outlet.
  • Page 17: Replacement Parts

    REPLACEMENT PARTS P/N 1011202 REV. C 11/16...
  • Page 18 Replacement Parts can be purchased from an authorized dealer. Contact A.J. Antunes & Co. at 1-630-754-1000 or toll free in the United States at 1-800-253-2991. Item Part # Description Qty. Item Part # Description Qty. Item Part # Description Qty.
  • Page 19: Notes

    NOTES P/N 1011202 REV. C 11/16...
  • Page 20 Equipment. 2. A.J. Antunes & Co. reserves the right to make changes in design or add any improvements on any product. The right is always reserved to modify equipment because of factors beyond our control and government regulations.

Table of Contents