Download Print this page

Infinity MODULUS II Service Manual page 10

Hide thumbs Also See for MODULUS II:

Advertisement

MSW-II
Power on Features
Power on Delay time
Power on LED
Normal On/Off
ATO
Transients/Pops
ATO Transient
Turn-on Transient
Turn-off Transient
Efficiency
Stand-by Input Power
AC Power Cons.@1W
Power Cons.@rated power
Efficiency
Protection
Short Circuit Protection
Thermal Protection
DC Offset Protection
Line Fuse Rating ( 120 V )
greater than 2 sec.
YES
--
green / red color
--
color
5 mV-peak
30 mV-peak
30 mV-peak
12 Watts
13 Watts
375 Watts
70 %
YES
--
YES
--
YES
--
3.15 Amps
AC Power Applied
Bi-color LED located adjacent to volume control knob
ATO mode only
"Active": green; "Standby": red
@ Speaker Outputs
@ Speaker Outputs
@ Speaker Outputs
typ.
@ nom. line voltage
typ.
@ nom. line voltage
typ.
@ nom. line voltage
typ.
@ nom. line voltage
Direct short at output
threshold ~ 65 deg. C at panel
DC present at Speaker Out lead Relay for driver/fire protection
Type ADL or MDL
AC Line cycled from OFF to ON
AC Line cycled from ON to OFF
Input power measured is REAL Watts, not VA
Panel mount fuse holder