12.7 Horizontal Airflow Direction Control

12.7.1
Auto Control
When the horizontal airflow is set to Auto using the remote control, the vanes swings left and right as shown in
the diagram.
When stopped with remote control, the discharge vanes are reset and stop at the reset position.
During Cooling operation or Soft Dry operation, indoor fan motor may stop to rotate at certain periods. At that
condition, the vane will stop swinging and rest at face front position.
12.7.2
Manual Control
When the horizontal airflow direction is set to Manual using the remote control, the automatic airflow is released
and the airflow direction vane move left and right in the range shown in the diagram.
The louver can be adjusted by pressing the button to the desired vane position.
When stopped with remote control, the vanes is reset and stopped at reset position.
Top View
60°
Reset
position / 0°
Face front position / 20°
Swing left and right
Top View
60°
45°
15°
30°