12.4 Indoor Fan Speed Control

Indoor fan speed can be set using remote control.
12.4.1
Fan Speed Rotation Chart
Fan Speed (rpm)
Speed
CS-C12UKF-2
Shi
Hi
Me
HLo
CLo
Lo-
SLo
Qhi
QMe
QLo
12.4.2
Automatic Fan Speed Control
When set to Auto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in the
table.
Fan speed rotates in the range of Hi, Me and Lo-
o
Deodorizing Control will be activated.
o
Manual
Normal
Manual
Quiet
Jetstream
Manual
Normal
Manual
Quiet
Mode Judgment
Auto Fan Speed during cooling operation:
1
Indoor fan will rotate alternately between off and on as shown in below diagram.
2
At the beginning of each compressor starts operation, indoor fan speed increases gradually for deodorizing
purpose.
3
For the first time the compressor operates, indoor fan will be switched to Hi fan speed from Lo- after 70
seconds from the start of compressor. This cause the room temperature to achieve the setting temperature
quickly.
4
During compressor stops, indoor fan will operate at Lo- for the beginning 20 seconds to prevent higher
volume of refrigerant in liquid form returning to the compressor.
5
After the compressor turned off for 3 minutes, indoor fan will start to operate at Lo- to circulate the air in the
room. This is to obtain the actual reading of the intake air temperature.
6
For the resume of compressor operation, indoor fan will operate at Me fan speed to provide comfort and
lesser noise environment, after 70 seconds from the restarts of compressor.
1330
1210
1030
890
850
810
790
1140
960
780
SHi
Hi
Me
Lo
Auto
QHi
QMe
QLo
Auto
o
Auto
Auto
Hi
Me
HLo
o
o
o
o
Hi-90
Me-90
Hi-90
Me-90
34
CLo
Lo-
SLo
o
o
CLo-90
o
o
o
o
o
Stop
o
o
o
o
o
o
o