Safety, Warnings, Installation Notes - Solahart 270HAV Owner's Manual And Installation Instructions

Air sourced heat pump water heater
Table of Contents

Advertisement

SAFETY, WARNINGS, INSTALLATION NOTES

It is important you read the following safety and warnings information.
SAFETY AND WARNINGS
This water heater is only intended to be operated by persons who have the experience or the knowledge
and the capabilities to do so.
This water heater is not intended to be operated by persons with reduced physical, sensory or mental
capabilities i.e. the infirm, or by children. Children should be supervised to ensure they do not interfere
with the water heater.
If the electrical supply conduit to the water heater is damaged, it must be replaced by a qualified person
in order to avoid a hazard. Phone your nearest Solahart Dealer to arrange for an inspection.
This water heater uses 220 V - 240 V a.c. electrical power for operation of the control systems and the
electrically operated components. The removal of the access covers will expose 220 V - 240 V a.c. wiring.
They must only be removed by a qualified person.
This water heater is supplied with an electronic thermostat, an over-temperature energy cut-out and a
combination temperature pressure relief valve. These devices must not be tampered with or removed.
The water heater must not be operated unless each of these devices is fitted and is in working order.
The Solahart warranty may not cover faults if relief valves or other safety devices are tampered
with or if the installation is not in accordance with these instructions.
DANGER: The operation of the over-temperature cut-out on the thermostat indicates a possibly
dangerous situation. If the over-temperature cut-out operates, it must not be reset and the water heater
must be serviced by a qualified person.
The heat pump will operate until a water temperature of 60°C is reached. If the ambient air temperature
is outside of the heat pump's operating range and heating of water is required, an electric heating unit will
heat the water temperature to 60°C.
"How Hot Should The Water Be?"
Refer to
The lever on the temperature pressure relief valve and expansion control valve (if fitted) requires to be
operated every six (6) months to clear any deposits and to ensure the valve and its drain line are not
blocked.
"Relief Valves"
Refer to
For continued safety of this water heater it must be installed, operated and maintained in accordance with
the Owner's Guide and Installation Instructions.
Servicing of the water heater must only be carried out by qualified personnel. Phone your nearest Solahart
Dealer.
Only a person qualified to install or service a water heater can drain the water heater, if this is required.
Do not modify this water heater.
In areas where there is a risk of freezing conditions, power must be available to the water heater at all
times and the electrical supply to the water heater should not be switched off, otherwise damage could
"Freeze Protection"
result (refer to
Do not use aerosols, stain removers and household chemicals in the vicinity of this water heater while
it is in operation. Gases from some aerosol sprays, stain removers and household chemicals are corrosive
to the materials used in the heat pump system.
Do not store swimming pool chemicals, household cleaners, etc., near the water heater.
Ensure the air flow, air inlet louvres and outlet grille are not obstructed in any way at any time.
on page 11 and to
"Minor Maintenance Every Six Months"
on page 8 and
on page 10 and to
"Electric Boosting"
"To Turn Off The Water Heater"
7
on page 10.
on page 29.
on page 12).

Advertisement

Table of Contents
loading

Table of Contents