6.0 - TRANSPORT, STORAGE AND DISPOSAL

• During transport the material needs to be handled with care, avoiding any impact or vibrations to the device;
• If the product has any surface treatments (ex. painting, cataphoresis, etc) it must not be damaged during transport;
• The transport and storage temperatures must observe the values provided on the rating plate;
• If the device is not installed immediately after delivery it must be correctly placed in storage in a dry and clean place;
• In humid facilities, it is necessary to use driers or heating to avoid condensation.
• At the end of its service life, the product is to be disposed of in compliance with the legislation in force in the country where
this operation is performed.

7.0 - WARRANTY

The warranty conditions agreed with the manufacturer at the time of the supply apply.
For damage caused by:
• Improper use of the device;
• Failure to observe the requirements described herein;
• Failure to observe the regulations pertaining to installation;
• Tampering, modification and use of non-original spare parts;
are not covered by the rights of the warranty or compensation for damage.
The warranty also excludes maintenance work, other manufacturers's assembling units, making changes to the device and
natural wear.

8.0 - RATING PLATE DATA

The rating plate data (see example provided here) includes the following:
• Manufacturer's name/logo and address (possible distributor name/logo)
• Mod.:
= device name/model followed
• CE-51AQ646
= certification pin number
• Gr. 2
= Mechanical resistance group 2
• EN 88-2
= Product reference regulation
• PS=Pe
= Maximum pressure or inlet pressure range at which product operation is guaranteed
• Pa
= Outlet pressure range
• AC
= Accuracy class of the regulator
• (-15...+60) °C
= Temperature range within which product operation is guaranteed
= In compliance with ATEX Dir. followed by the protection mode
= Conformity with Regulation (EU) 2016/426 followed by Notified Body No.
= In compliance with PED directive followed by Notified Body No.
• year
= Year of manufacture
• Lot
= Product serial number (see explanation below)
• U1823
= Lot issued in year 2018 in the 23
• 14216
= progressive job order number for the indicated year
• 00001
= progressive number referring to the quantity of the lot
RG/2MC - FRG/2MC
by the connection diameter
in accordance with EN 13611
Mod.: RG/2MC DN 65
CE-51AQ646 - EN 88-2 - Gr.2
Pa: 13-23 mbar - AC=10
0051
0497
year: 2018
week
rd
16
Madas Technical Manual - REV. 0 of 10
Via Moratello, 5/7 - 37045
Legnago (VR) - Italy
www.madas.it
PS=Pe:0,5÷1 bar
(-15...+60) °C
Lot:U1823
14216/00001
May 2018
th