HORIZONTAL LEFT-RIGHT VENT CONFIGURATION
Fig. 55 – Horizontal Left (Appearance May Vary)
See "Notes for Venting Options"
HORIZONTAL RIGHT-VERTICAL VENT CONFIGURATION
NOTES FOR VENTING OPTIONS
1. Attach vent pipe adapter with gasket to furnace casing.
2. Align notches in rubber coupling over standoffs on adapter. Slide clamps over the coupling.
3. Slide vent pipe through adapter and coupling into vent elbow.
4. Insert vent pipe into vent elbow.
5. Torque all clamps 15 lb.-in.
6. Attach combustion air pipe adapter with gasket to furnace.
7. Attach combustion air pipe to adapter with silicone. Pilot drill a1/8-in. hole in adapter and secure with a #7 x 1/2-in. sheet metal screw.
Avoid short horizontal offsets with 90
deg. Elbows. Short offsets can be
difficult to slope and may trap con-
densate.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
A11329A
ALTERNATE
COMBUSTION
AIR CONNECTIONS
A11337
Use 45 deg. Elbows where
possible, to ensure conden-
sate drainage.
Fig. 57 – Near Furnace Vent Connections
Requires Internal Vent Kit
See Product Data for Current Kit Number
HORIZONTAL RIGHT - LEFT VENT CONFIGURATION
Fig. 56 – Horizontal Right (Appearance May Vary)
See "Notes for Venting Options"
Slope vent pipe back to the
furnace at least ¼" per foot
49
ALTERNATE
COMBUSTION
AIR CONNECTIONS
A11336
A11335
A14546