The aftercooler and/or optional precooler require a source of city, tower, or chiller water
and a discharge or return line. You can use water at temperatures of 45 to 85°F {7 to 29°C}.
The water flow should be at least 3 gal/min {11.4 liters/min}.
Aftercooler Inlet
Aftercooler Outlet
IMPORTANT: Turn the water off when the dryer is
not in use to prevent condensation.
( W 6 0 0 - 1 0 0 0 )
1
Connect the water supply line to
the aftercooler or precooler inlet.
If a manual shut off valve is used,
it should be mounted on the inlet
line. Conair recommends that both the
supply and return water lines have a shut
off valve.
2
Connect the water discharge or
return line to the aftercooler or
precooler outlet.
Recommended Water Flow Rates
Dryer Model
gal./min. {liters/min.}
600
800
1000
1300
1600
2000
2400
3200
4000
5000
IMPORTANT: Make the
water supply and
discharge / return
connections with
flexible hoses at
least 24 in. (61 cm)
long. This allows you
to easily remove the
aftercooler assembly
for cleaning.
TIP: If an optional
flow control is also
being installed with
the aftercooler, the
manual shut off valve
should be installed
on the inlet line for
the flow control.
15 {56.8}
15 {56.8}
20 {75.7}
25 {94.6}
25 {94.6}
25 {94.6}
25 {94.6}
30 {113.6}
30 {113.6}
30 {113.6}
NOTE: Models
W600-1000 dryer
aftercooler and dry
air delivery configu-
ration shown.
Location on larger
models are differ-
ent. Refer to the
labeling on your
dryer.
3 - 1 3
I n s t a l l a t i o n l