Mobile Hoist. The information in this manual is important for the safety of anyone near the Mackworth Essentials 180 Mobile Hoist and must be read and understood to help prevent injuries. It is also crucial to the proper operation and maintenance of the Mobile Hoist.
1.4 Symbols Used The Table below includes all Symbols from BS EN ISO 15223-1:2016 that can be found in this Manual and on the Product and what they represent. Refer back to this Table when you are unsure of what a symbol represents. Consult instructions before use Caution –...
• The Mackworth Essentials 180 Mobile Hoist is intended to be installed on a flat and levelled surface prior to use. • The Hoist must be installed only by persons authorised by Prism Medical UK or who have the rights to install and commission the Hoist safe for use.
2. ALL Mobile Hoists are dangerous to the person being transferred when used recklessly or pushed at speed. 1.8 Operating Environment The Mackworth Essentials 180 Mobile Hoist is suitable for use within the professional health care facility environment as well as the home health care environment.
COMPONENTS / KEY PARTS Please see below to familiarise yourself with the components of the Mackworth Essentials 180 Mobile Hoist. The image below show the contents of the Hoist. If you have not received all the components contact Prism Medical UK dealer immediately –...
ASSEMBILY INSTRUCTIONS 3.1 Unpacking Some of the parts are heavy and will need to be lifted with care. Items weighing over 20kg will require a two person lift. Please refer to (7.0) technical specifications for components weights. The Hoist will arrive to you in a robust box, please be careful when removing the components from the box. Please read the user guide in full before operating.
3.3 Hoist Assembly A. Carefully open the box and remove all loose parts and excess packaging from the box. 2 person lift recommended for the following points. B. Carefully holding onto the handle and boom, lift the Hoist components out of Figure 3 the box.
3.4 Electrical Connections Connect all the cables to the control box as shown in the pictures opposite. A. Connect the lift actuator cable connector to the second port (marked No. 1) from the left side of the control box (as shown in Fig. 7). Figure 7 B.
Figure 13 5.2 Raising and Lowering The up and down movement of the boom on the Mackworth Essentials 180 Mobile Hoist is achieved by an electric actuator which is controlled by hand control. The hand control has two buttons with directional arrows up and down. The actuator stops automatically at the limit of travel in both directions.
5.4 Emergency Stop Button Figure 17 The Mackworth Essentials 180 Mobile Hoist is fitted with an Emergency Stop button. Push the Emergency Stop button (as shown in Fig. 17) to cut all power to the Mobile Hoist. To resume power, release the emergency stop button by turning in a Figure 18 clockwise direction.
5.7 Battery The battery pack should never be stored for long periods of time without a regular charge. The battery pack is protected in an encased unit located on top of the control box, on the rear of the product. The control box, below the battery, will inform the user when the battery is flat and requires charging, by an illuminated LED.
BS EN ISO 10535 before its use. The slings with a safe working load of 180kg that can be used with the Mackworth Essentials 180 Mobile Hoist are shown below in Table’s 3 and 4, complete with product codes. For all components, the lowest maximum safe working load must always be adhered to.
Page 16
Size Mackworth Sling Range - Product Material and Code Polyester Solid Polyester Mesh Parasilk Quilted Supersoft Spacer Mackworth Oak Small 1201OK7500 1201OK8500 1201OK3500 1201OK5500 1201OK4500 Medium 1201OK7400 1201OK8400 1201OK3400 1201OK5400 1201OK4400 Large 1201OK7300 1201OK8300 1201OK3300 1201OK5300 1201OK4300 1201OK7200 1201OK8200 1201OK3200...
Page 17
1201WL7200 1201WL7100 XXXL 1201WL7000 Mackworth Willow with head support Small 1201WL7520 This sling is made up of a single quilted material backed with solid polyester material. Medium 1201WL7420 Large 1201WL7320 1201WL7220 1201WL7120 XXXL 1201WL7020 Mackworth Beech Small 1201BC7500 1201BC8500 1201BC3500...
Page 18
CA300PP5 CA300MP5 CA300SP5 CA300PAP5 X Small CA300PXS CA300MXS CA300SXS CA300PXS Small CA300PS CA300MS CA300SS CA300PAS Small/Medium CA300PSM CA300MSM CA300SSM CA300PASM Medium CA300PM CA300MM CA300SM CA300PAM Medium/Large CA300PML CA300MML CA300SML CA300PAML Large CA300PL CA300ML CA300SL CA300PAL X Large CA300PXL CA300MXL CA300SXL CA300PAXL CA400 Universal Deluxe CA400PP1...
Page 19
Medium CA501PM CA501MM CA501SM CA501PAM Medium/Large CA501PML CA501MML CA501SML CA501PAML Large CA501PL CA501ML CA501SL CA501PAL X Large CA501PXL CA501MXL CA501SXL CA501PAXL CA502 Toilet Access with head support CA502PP1 CA502MP1 CA502SP1 CA502PAP1 CA502PP2 CA502MP2 CA502SP2 CA502PAP2 CA502PP3 CA502MP3 CA502SP3 CA502PAP3 CA502PP4 CA502MP4 CA502SP4 CA502PAP4...
Page 20
Small CA600PS CA600MS CA600SS CA600PAS Small/Medium CA600PSM CA600MSM CA600SSM CA600PASM Medium CA600PM CA600MM CA600SM CA600PAM Medium/Large CA600PML CA600MML CA600SML CA600PAML Large CA600PL CA600ML CA600SL CA600PAL X Large CA600PXL CA600MXL CA600SXL CA600PAXL CA700 Classic Hammock CA700PP1 CA700MP1 CA700SP1 CA700PAP1 CA700PP2 CA700MP2 CA700SP2 CA700PAP2 CA700PP3...
Page 21
Large CA701HSPL CA701HSML CA701HSSL CA701HSPAL X Large CA701HSPXL CA701HSMXL CA701HSSXL CA701HSPAXL CA702 Comfort In Chair Hammock CA702PP1 CA702MP1 CA702SP1 CA702PAP1 CA702PP2 CA702MP2 CA702SP2 CA702PAP2 CA702PP3 CA702MP3 CA702SP3 CA702PAP3 CA702PP4 CA702MP4 CA702SP4 CA702PAP4 CA702PP5 CA702MP5 CA702SP5 CA702PAP5 X Small CA702PXS CA702MXS CA702SXS CA702PAXS Small...
DETACHABLE PARTS Detachable parts that are included with the product consist of the Battery and the QRS (Quick Release System) Carry Bar. This is an optional accessory that is not included with the standard product. Below are the instructions for attaching and detaching the QRS Carry Bar and the Battery. 6.1 Attaching/detaching QRS (Quick Release System) Carry Bar If you have chosen to have QRS carry bar please follow the following section to attach and detach the carry bar from hoist.
6.2 Attaching/detaching the Battery The attachment and detachment of the Battery can be completed safely by following the following procedure: Attach 1. Grab Hold of the Battery from the top position as shown in figure 35 and place your fingers onto the latch. 2.
TECHNICAL SPECIFICATION 7.1 Mackworth Essentials 180 Mobile Hoist Dimensions All dimensions below are shown in millimetres. Figure 38 Figure 39 | 24 of 40 999051 – Revision B P a g e...
7.2 Specifications Dimensions Turning Circle 1010mm Overall height 2010mm Overall Width 625mm Ground clearance 15mm Front and Rear Casters Size 75mm and 100mm Table 5 Weights: Safe Working Load (SWL) 180 kg Full product 40 kg Base Assembly 18.5 kg Mast &...
ENVIRONMENTAL - STORAGE AND OPERATING CONDITIONS The Mackworth Essentials 180 Mobile Hoist is intended for internal use within normal environmental conditions. It is not intended to be used in environments where there are rapid changes in the environmental temperature and humidity during use.
FAULT FINDING If a problem arises with the Mobile Hoist, the Table below will hopefully assists in determining the fault and what actions you can take. If the fault cannot be found or the fault is found and the action guide does not provide a fix (e.g. – a damaged wire would need replacement), contact your local Prism Medical UK authorized dealer immediately, a service engineer will be required to repair the Hoist.
CLEANING 11.1 Service No service is to be carried out on the Mackworth Essentials 180 Mobile Hoist, while transferring a person to reduce the risk of injury. Service must be completed by a Prism Medical UK authorised Service Engineer. Do not attempt to service the product yourself, or warranty is void.
11.2 Inspection Inspection is to be completed prior to each use by the user of the Mobile Hoist. Should any of the components in the table below fail the inspection, DO NOT use the Mobile Hoist. Contact your local authorised dealer for service – contact details are on the last page of this manual. Ensure all component inspections in the Table below are completed prior to each use of the Hoist.
11.3.1 General cleaning It is recommended to clean the Mackworth Essentials 180 Mobile Hoist and accessories before the use by a different patient, reducing the risk of cross–contamination. The exterior of the Mackworth Essentials 180 Mobile Hoist can be cleaned using a damp soapy cloth for general cleaning duties.
This guarantee does not affect or in any way limit your Statutory Rights. 1. Prism Medical UK guarantees the Mackworth Essentials 180 Mobile Hoist, supplied as new, against failure within the period of 12 months from the date of purchase by virtue of defects in material or workmanship. (Excluding Batteries).
Page 37
User notes: | 37 of 40 999051 – Revision B P a g e...
Page 38
User notes: | 38 of 40 999051 – Revision B P a g e...
Page 39
User notes: User notes: | 39 of 40 999051 – Revision B P a g e...
Page 40
Dealer/service contact details: Manufacturer contact details: Prism Medical UK Address: Unit 1 • Tir Llwyd Industrial Estate • St Asaph Avenue • Kinmel Bay • Conwy • LL18 5JZ Telephone Number: 01924 840100 Disclaimer While every effort has been made to ensure the accuracy of information contained in this user manual, no liability can be accepted by Prism Medical UK for any errors or omissions.
Need help?
Do you have a question about the Essentials 180 and is the answer not in the manual?
Questions and answers
What is the reach of the Mackworth 180 ?
The Mackworth Essentials 180 Mobile Hoist has an impressive lifting range that extends all the way from the floor.
This answer is automatically generated