Page 1
Modular Air Cleaning Systems Owner’s Manual...
Page 2
For quick future reference, fill in the system information in the spaces below. Should you need assistance, call the Parker Customer Service number shown below. To expedite your service, have the following information available when contacting Parker.
UV lamp operation and filter element condition. local and national codes and regulations. • The CRYSTAL-AIRE uv system should not be used for ® • Do not operate UV without complete lamp enclosure in support of personnel or material.
Page 5
Installation of evaluate and understand potential combustion or deflagration Parker equipment should be by a licensed contractor that is hazards that may exist. In addition, NFPA standards require also experienced in potential fire and explosion hazards and...
CRYSTAL-AIRE uv system should be established by your local ® Standard 170: Ventilation of Health Care Facilities. CRYSTAL- AIRE uv distributor or by PARKER sales represen- ® tative. When correctly applied, the CRYSTAL-AIRE uv may ® We have manufactured an air cleaner engineered to rigid help meet the ASHRAE reopening of schools and universities specifications and quality control checks.
Page 7
CHART 1 ACHCFM CHART for ROOM SIZES and AIR CHANGES PER HOUR (ACH) 150 ft 300 ft 400 ft 500 ft 600 ft 750 ft 1200 ft # ACH 10x15 15x20 20x20 20x25 20x30 25x30 30x40 1200 1125 1800 1000 1200 1500 2400...
Notify your delivery carrier immedi- ately and enter a claim if any damage is found. Wall Mounting: 1. Remove the wall bracket from CRYSTAL-AIRE ® Unpacking 2. Locate an appropriate area on the wall to mount the...
Page 9
CRYSTAL-AIRE ® and the UV lamp will illuminate. It is typical that there is a slight fan delay on start-up and when changing speeds. 1. To install, carefully raise the CRYSTAL-AIRE uv to the ® mounting location. a. USE CAUTION WHEN LIFTING, UTILIZE LIFTING...
Page 10
FILTRATION / UV FUNCTION In any CRYSTAL-AIRE uv system, contaminated air is drawn ® PREFILTER through a 4 stage filtration chamber, cleaned and conditioned, This is a one-inch-thick disposable MERV 8 filter consist- then exhausted by the system blower. Airborne particles, both ing of pleated, glass fiber media inside a metal frame.
Page 11
The electrical interlock switch prevents power to the blower The power on/off switch is located on the outside of the and UV lamp when the access door or the pre-filter is not CRYSTAL-AIRE uv as part of the control panel area. This is a ®...
D A N G E R The following procedures will expose hazardous live and moving parts. Switch Off/isolate the electrical supply to the CRYSTAL-AIRE uv system. ® Due to the simplicity of the design, breakdowns are restricted to these components: •...
Page 13
FILTERS The pre-filter, main filter and carbon filter will require periodic replacement. Refer to filter changeout section below, however actual pre-filter and main filter replacement interval may vary depending on the quality of the air that which is being filtered. For dirty and dusty environments, the pre and main filter will require more frequent replacements whereas a cleaner envi- ronment will require less frequent pre and main filter replace-...
Page 14
PARTS ORDERING PART DESCRIPTION PART NUMBER REFERENCE Mobile Unit 01-10258-00 Wall Unit 01-10258-01 Ceiling Unit 01-10258-02 Hanging Unit 01-10258-03 Pre-filter DPHT-101 Main Filter MERV 13 2809349 Main Filter MERV 14 2909237 Main Filter HEPA 2971351 Power Switch EX0040-1 Fan Speed Selector Switch 20-2755 Indicator Lamp 20-1064...
Page 15
PARTS ORDERING Power Switch Fan Speed Selector Switch Odor Filter Fan Speed Selector Switch Knob Indicator Lamp Fuse Fan Motor Speed Selector Switch UV Lamp Differential Pressure Switch UV Lamp Ballast Caster Transformer Door Interlock Switch Main Filter HEPA, Optional MERV 13/14 Prefilter...
Increase blower speed. (Refer to Fan Speed Selector, page 11). Contact your local distributor or Parker E. Fan on/off switch is on and 1. Faulty lamps Replace lamps illuminated, fan is operating, UV 2.
Page 17
CRYSTAL-AIRE uv SYSTEM WIRING DIAGRAM ®...
Page 18
MCB, PNP, SDC, SFC, and SHM series will be free from defects in materials and workmanship for ten (10) years from the date of shipment from Parker. Subject to the terms and conditions hereof, warrants to the original Buyer...