SECTION 2
SECTION 2
Heliarc 252
115V AUX
I I
REMOTE
CONTROL
WORK
Work
Remote Contactor/Current Control
* Not supplied with power source.
/
AC
DC
AC
Connect to approved earth
ground. (by customer)
Figure 2-5 - Heliarc 252/352 Interconnection Diagram
Figure 2-7 - Heliarc 252/352 Interconnection Diagram
Note: Three power cable adaptors are supplied with the
power source.
Use P/N 19708 for connecting HW-9 & HW-24 style
torches.
DCSP
Use P/N 19709 for connecting HW-26 style torches.
DCRP
Use P/N 19710 for connecting HW-17 style torches.
Water to Torch
Power/Water from Torch
Power/Gas to Torch
"Electrically Hot" power connection block. (see Note)
Disconnect primary power before changing connec-
ELECTRODE
tions.
* Covered Electrode
(SMAW) Holder
* Gas Cooled
* FC-5B Foot Control P/N 33646
* FC-5B EHD Foot Control P/N 33841
* TC-2B Torch Control P/N 33839
* HC-3B Hand Control P/N 33838
20
19
INSTALLATION
INSTALLATION
Heliarc Tig Torch
* Water Cooled
Heliarc Tig Torch