Advertisement

Quick Links

Operating and
Service Manual
ATH800M6G
Model
10037108
Part Number
Serial Number
160 School House Road, Souderton, PA 18964 • 215-723-8181 • Fax 866-859-0582 • www.arworld.us

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ATH800M6G and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AR ATH800M6G

  • Page 1 Operating and Service Manual ATH800M6G Model 10037108 Part Number Serial Number 160 School House Road, Souderton, PA 18964 • 215-723-8181 • Fax 866-859-0582 • www.arworld.us...
  • Page 3 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 18 December 2006 concerning the Registration, Evaluation, Authorization and Restriction of Substances of Very High Concern Chemicals (SVHC) Supporting documentation is held by AR RF/Microwave Instrumentation’s Quality department in Pennsylvania, United States. Place of issue:...
  • Page 5 The caution symbol denotes a potential hazard. Attention must be given to the statement to prevent Your AR equipment may have more than one power supply cable. Use damage, destruction, or harm. only approved power cable(s). If you have not been provided with a Dangerous voltages are present.
  • Page 6 EQUIPMENT CONTAINING LASERS risk of serious injury due to unsafe AR Field Probes (FL/PL Series) and Field Analyzers (FA product handling should be a fundamental Series) are Class 1 laser products containing embedded consideration every user.
  • Page 7 Zur Vermeidung von Personen- oder Sachschäden gilt BEVOR SIE DAS GERÄT ANSCHLIESSEN es, die Hinweise zu beachten. Ihre AR-Ausrüstung hat möglicherweise mehr als ein Stromversorgungskabel. Gefährliche elektrische Spannungen sind vorhanden. Verwenden Sie nur zugelassene Stromkabel. Falls Sie kein Stromkabel oder Höchste Vorsicht ist geboten.
  • Page 8 Die meisten Geräte müssen während des Versands, der Montage und des Gebrauchs LASER-INFORMATION transportiert werden. Jeder Nutzer sollte sich AR - Feldsonden (FL/PL-Serie) und Feldanalysatoren (FA-Serie) über das Risiko von schweren Verletzungen sind Laserprodukte der Klasse 1 mit eingebetteten Klasse-4- durch unsachgemäße...
  • Page 9 électrode de mise à la Votre équipement AR peut disposer de plus d’un câble d’alimentation terre de protection. électrique. Utilisez uniquement un ou des câbles d’alimentation approuves.
  • Page 10 éliminer le risque injustifié de blessures causées par le levage est fournie par les méthodes de travail de NIOSH (publication Les sondes de champ AR (série FL/PL) et les analyseurs de n° 94-110) disponibles sur : champ (série FA) sont des produits laser de classe 1 contenant des lasers intégrés de classe 4.
  • Page 11 Er zijn gevaarlijke elektrische spanningen aanwezig. Wees uiterst voorzichtig. VOOR HET OPZETTEN VAN DE STROOM Uw AR-apparatuur kan meer dan een netvoedingskabel bezitten. Gebruik alleen goedgekeurde netvoedingskabel(s). Koopt een Wijst op een terminal aan die bedoeld is voor aansluiting netvoedingskabel die is goedgekeurd voor gebruik in uw land als u...
  • Page 12 APPARAAT DAT LASERS BEVAT distributie, de assemblage en het gebruik moeten worden behandeld, moet het risico AR-terreinsondes (FL/PL-serie) en terreinanalysatoren (FA- op ernstig letsel als gevolg van een serie) zijn laserproducten van klasse 1 met ingesloten onveilige behandeling van het product een klasse 4-lasers.
  • Page 13: Table Of Contents

    General Caution Notes ..................2 TYPICAL CURVES ..................7 General ......................7 Model ATH800M6G VSWR vs Frequency (GHz) ..........7 E-Plane Radiation Pattern 800 MHZ ..............8 H-Plane Radiation Pattern 800 MHZ ..............8 E-Plane Radiation Pattern 1.0 GHZ ..............9 H-Plane Radiation Pattern 1.0 GHZ ..............
  • Page 14 Model ATH800M6G...
  • Page 15: General Information

    0.8–6.0 GHz. The Model ATH800M6G has a power-handling capability of 1500 watts (W) with a minimum gain of 11dBi at 0.8 GHz, typically increasing more than 22dBi at 6.0 GHz.
  • Page 16: General Caution Notes

    1.4.2 General Caution Notes CAUTION: The Model ATH800M6G is capable of generating output voltages that are dangerous to human life and can cause serious microwave burns to human tissue. Therefore, never stand or walk in front of the antenna when it is radiating microwave energy.
  • Page 17 Based on the popular ATH800M5GA, the ATH800M6G has similar performance through 5GHz, with additional frequency coverage up to 6GHz, and is ideal for use with AR’s 6GHz am- plifier models. Specially designed septums are installed to focus the energy ensuring the intensi- ty of the field for 3 meter testing.
  • Page 18 CW Input Power ATH800M6G 7-16 DIN Female See Input Power Chart ATH800M6GM1 N Female See Input Power Chart ATH800M6GM2 SC Female See Input Power Chart ATH800M6GM3 7/8” EIA See Input Power Chart ATH800M6GM4 1-5/8” EIA See Input Power Chart ATH800M6G 3dB Beamwidth...
  • Page 19 Field strength also varies with frequency and position of antenna and EUT in non-anechoic testing environment. To order AR Products, call 215.723.8181. For an applications engineer call:800.933.8181. Direct to Service call: 215.723.0275 or email: service@arworld.us For Faxing Orders:866.859.0582 (Orders Only Please)
  • Page 21: Typical Curves

    2. TYPICAL CURVES GENERAL This section contains typical curves showing VSWR versus frequency and E-plane and H-plane radiation patterns at various operating frequencies for the Model ATH800M6G Microwave Horn Antenna. MODEL ATH800M6G VSWR VS FREQUENCY (GHZ) Rev B...
  • Page 22: E-Plane Radiation Pattern 800 Mhz

    Model ATH800M6G E-PLANE RADIATION PATTERN 800 MHZ -180 -150 -120 Degrees H-PLANE RADIATION PATTERN 800 MHZ -180 -150 -120 Degrees Rev B...
  • Page 23: E-Plane Radiation Pattern 1.0 Ghz

    Model ATH800M6G E-PLANE RADIATION PATTERN 1.0 GHZ -180 -150 -120 Degrees H-PLANE RADIATION PATTERN 1.0 GHZ -180 -150 -120 Degrees Rev B...
  • Page 24: E-Plane Radiation Pattern 2.0 Ghz

    Model ATH800M6G E-PLANE RADIATION PATTERN 2.0 GHZ -180 -150 -120 Degrees H-PLANE RADIATION PATTERN 2.0 GHZ -180 -150 -120 Degrees Rev B...
  • Page 25: E-Plane Radiation Pattern 3.0 Ghz

    Model ATH800M6G E-PLANE RADIATION PATTERN 3.0 GHZ -180 -150 -120 Degrees 2.10 H-PLANE RADIATION PATTERN 3.0 GHZ -180 -150 -120 Degrees Rev B...
  • Page 26: E-Plane Radiation Pattern 4.0 Ghz

    Model ATH800M6G 2.11 E-PLANE RADIATION PATTERN 4.0 GHZ -180 -150 -120 Degrees 2.12 H-PLANE RADIATION PATTERN 4.0 GHZ -180 -150 -120 Degrees Rev B...
  • Page 27: E-Plane Radiation Pattern 5.0 Ghz

    Model ATH800M6G 2.13 E-PLANE RADIATION PATTERN 5.0 GHZ -180 -150 -120 Degrees 2.14 H-PLANE RADIATION PATTERN 5.0 GHZ -180 -150 -120 Degrees Rev B...
  • Page 28: E-Plane Radiation Pattern 6.0 Ghz

    Model ATH800M6G 2.15 E-PLANE RADIATION PATTERN 6.0 GHZ -180 -150 -120 Degrees 2.16 H-PLANE RADIATION PATTERN 6.0 GHZ -180 -150 -120 Degrees Rev B...
  • Page 29: Outline Drawing

    3. OUTLINE DRAWING An outline drawing (Drawing Number 10037109) of the Model ATH800M6G Microwave Horn Antenna is shown below. Drawing 10037109, Rev A Rev B...
  • Page 30 Model ATH800M6G Rev B...
  • Page 31: Polarization Of Horn Antennas

    4. POLARIZATION OF HORN ANTENNAS Rev B...
  • Page 32 Model ATH800M6G Rev B...
  • Page 33 These modules are not field-repairable and should never be opened outside of AR’s Microelectronics Lab. The modules in these product lines have a security label on two sides of the modules between the housing and lid/cover. If the security label is removed and or cut, the warranty of the module will be voided.

This manual is also suitable for:

10037108