Operation; Maintenance - Dimplex PPC Series Manual

Electronic convector
Hide thumbs Also See for PPC Series:
Table of Contents

Advertisement

Available languages

Available languages

Wiring Diagram
Thermal Cutout

Operation

CAUTION: This panel convector must be properly installed before
it is used.
CAUTION: Prior to energization remove all construction dirt
(plaster, sawdust, etc.) from interior and exterior of panel convector.
CAUTION: Avoid direct contact of paper, fabric, or furniture with
panel convector, to prevent a possible fire.
Dimplex panel convectors are designed and tested for safe and
trouble-free operation. Free airflow throughout the panel convector is
very important for the most efficient operation of the panel convector.
All Dimplex panel convectors are protected against overheating by
a built-in thermal cutout. A thermal cutout will switch off the heater if
for any reason it overheats. Should the cutout operate, disconnect
heater from power supply and determine the reason for overheating.
Resolve the reason for overheating before attempting to use the
heater again. To reset the heater it is necessary to switch off the
power to the heater for several minutes.
The PPC features CONNEX
with Dimplex single and multi-zone CONNEX
simple whole home connectivity and comfort. CONNEX
are available to control one or multiple CONNEX
50 ft. (15 m) radius.
When power is first supplied to the PPC the Setpoint Temperature
will flash in the temperature display area. At any time either the + or
� button can be pressed to have the temperature setpoint displayed
again.
A. Setting/Temperature Display
The PPC is designed to control the temperature of a room anywhere
from 32-86°F (0-30°C). Pressing the + or � will increase or decrease
the desired temperature for the room to be heated by 0.5° (in either
°C or °F).
After 5 seconds the Setpoint Temperature will switch to display the
intake temperature of the room.
!
NOTE: Pressing the + and � at the same time will toggle between
°C and °F.
B. Economy Setting
The Economy Setting can be used to change the Setpoint Temperature
for a variable period of time. By pressing the V the Economy Setting
will be enabled - signified by the icon flashing. After the Set Back
Temperature has been set, the icon will become solid after three
seconds and the Set Back Temperature will be enabled.
To return back to the Comfort Setting press the V button and the
icon will disappear and the
C. Set Back Temperature Setting
The Set Back Temperature Setting is used during periods when the
Economy setting feature is active. This temperature adjustment can
be set by pressing the V followed by the + or � .
D. Comfort Setting
The Comfort Setting icon will be displayed when the heater is in
normal operation based on the Setpoint Temperature for the room.
2
Ground
Temperature
Sensor
, a wireless technology that works
TM
controllers to provide
TM
TM
heaters within a
TM
icon will appear.
Figure 2
L1
A
L2
C
B
D
A - Setting/Temperature Display
B - Economy Setting Icon
C - Set Back Temperature Setting
D - Comfort Setting Icon
E - Synchronized Icon
!
NOTE: Either the
on the setting being used.
E. Synchronized Icon
The PPC and the controller will need to be synchronized, to operate
together. To do this:
1.
On the PPC heater press and hold the V button for 3 seconds,
both the
Press the � , + and then V, on the PPC heater.
2.
3.
Within 10 seconds press any button once on the CONNEX
controller.
!
NOTE: There is a 3 second delay between pressing the last button
the CONNEX
!
NOTE: To desynchronize a PPC heater from the synchronized
controllers
CONNEX
controller, on the PPC heater:
TM
1. Press and hold the V for 3 seconds.
2. Press the V, + and then � .
Nothing needs to be done to the CONNEX
Dimplex single and multi-zone CONNEX
separately and are available for purchase from your authorized
Dimplex dealer.
To find your local Dimplex dealer, visit www.dimplex.com.
F. Lock Icon
The Panel Proportional Convector Heater has a Button Lock feature,
to prevent settings from accidentally being changed.
1.
Press and hold the V for 3 seconds. Both the
will begin to flash.
To Enable: Within 5 seconds press +, then � , then +, then � .
2.
The
icon will now be visible.
To Disable: Within 5 seconds press � , then +, then � , then +.
The
icon will not be visible.
!
NOTE: The PPC can be locked in either the Comfort or Economy
Setting. Ensure that the desired icons are present when locking is
complete.

Maintenance

WARNING: Disconnect power and allow the unit to completely
cool before attempting any maintenance or cleaning to reduce the
risk of fire, electric shock, or damage to persons.
CAUTION: The heater should not be operated with an accumula-
tion of dust or dirt on or in the unit, as this can cause a build up
of heat and eventual damage. For this reason the heater must be
inspected regularly, depending upon conditions and at least at
H
G
F
I
E
F - Lock Icon
G - Decrease Button
H - Increase Button
I - Menu Button
or
icon will always be visible, dependent
and
icons will begin to flash.
controller and the PPC heater.
TM
TM
controller.
TM
controllers are sold
TM
and
Icons
www.dimplex.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ppc0500Ppc1000Ppc1500Ppc2000

Table of Contents