Single Surface Unit(Lr, Rr); Single Surface Unit(Rf) - LG LRE3194ST Service Manual

30” freestanding electric range
Hide thumbs Also See for LRE3194ST:
Table of Contents

Advertisement

Components
Single surface units:
Left Rear(LR)
Right Rear(RR)
Element
Test procedures
1. Refer to page 3-6 for the servicing procedure
2. Set the Multiple meter scale to the R x 1
3. Disconnect wires from cook-top elements
4. Touch the ohmmeter test leads to the element
terminal and 1A.
The meter should indicate 46 Ω ± 10%
2A
5. Touch the ohmmeter test leads to limiter
terminals 1B and 2B.
With the temperature below 150˚F, the meter
should indicate an open circuit(infinite).
With the temperature above 150˚F, the meter
should indicate continuity (0Ω).
1B
2B
1A
4-4
Results
Normal: Approximately 46 Ω,
If not replace
Below 150˚F
M open circuit(infinite).
Above 150˚F
M continuity (0 Ω)
Element
Element
terminal
terminal

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lre3194bdLre3194bm

Table of Contents