-Guard that the hydro accumulator has discharged completely before use. The function of the p -Guard can be combined with the following HYDAC accumulator systems: Bladder accumulators, piston accumulators, diaphragm accumulators, metal bellows accumulators as well as back-up type hydraulic accumulators and accumulator stations.
Assembly The installation of the EDS 3400 is carried out on the fluid side. The EDS 3400 is mounted via the pressure port as close as possible to the accumulator (Example: to the left of the diaphragm accumulator via a safety and shut-off block SAF).
EDS 3400 CAUTION: The EDS 3400 must be fitted using a suitable open-end wrench (across flats 27) on the hexagon nut of the pressure connection. Inappropriate installation methods, such as manually fitting above the housing can damage the housing or even cause the device to fail completely, due to the rotatability of the EDS 3400.
EDS 3400 Reading the digital display Representation on ASCII Description 7-segment display representation Accumulator precharge p Switch-of value not yet determined n. A . n.A. Actual system pressure Max value pre-set, output 1 (display only) Switch point, output 1 Switch point, output 2...
RP2 and P.Low. The pressure must be P.Low when the hydro accumulator is completely emptied in order to enable the software of the EDS 3400 to complete the monitoring and to show p0 in the display. Check if p is displayed in the "main menu".
For detailed information on IO-Link device parameters, factory defaults, process and diagnostic data, supported standard system commands as well as additional HYDAC device specific system commands for the various product versions (part numbers), please refer to the corresponding IODD (IO Device Description).
EDS 3400 MANUAL PARAMETERISATION ON THE DEVICE The EDS 3400 can be parameterised via the device keys PARAMETERISATION WITH HYDAC PROGRAMMING DEVICE HPG P1-000 (Connection with standard cable) HPG P1 Device Q1 / C PARAMETERISATION WITH HYDAC PROGRAMMING ADAPTER ZBE P1-000...
EDS 3400 10 Output settings 10.1 SWITCHING OUTPUTS The EDS 3400 has 2 switching outputs whose switching behaviour (setting pre-charge pressure monitoring or twopoint mode) is parameterisable. In addition to the IO-Link Smart Sensor Profile Specification, a switch and switch-back delay can be set in HYDAC IO-Link sensors.
EDS 3400 10.1.2 Setting of the pre-charge pressure monitoring The pre-charge pressure monitoring is determined by the switching value ("FL1). This is calculated as described in the following and can be checked in the main menu. = T.VAL – Td.Lo The output switches as soon as p leaves this range.
EDS 3400 11 Basic Settings The EDS 3400 can be adapted to suit the particular application as required by changing multiple settings. These settings are combined in a menu shown by the example of a –Guard with a measuring range of 0 .. 250 bar.
EDS 3400 12 Changing the Basic Settings NOTE: When the menu is activated, no switching operations are carried out! NOTE: If there has been no activity in this menu for approx. 60 seconds, the menu will automatically close and any changes you have made will not be applied.
EDS 3400 15 Program enable The instrument has a program enable which must be set to change the settings. The program enable can be set or cancelled during operation. It provides protection against unintentional alterations of settings. 15.1 CHANGING THE PROGRAM ENABLE In the extended functions menu, please press the key "...
EDS 3400 17 PIN connection M 12x1, 4 pole Q1/C Q2/QA Signal Description Q2/QA Switching output for the accumulator charging function (SP2) / Analogue output Q1/C Switching output for the p – guarding function (SP1) / IO-Link communication Status: 2018-07-30 HYDAC INTERNATIONAL GMBH Part No.: 670000 E...
EDS 3400 20 Accessories 20.1 FOR ELECTRICAL CONNECTION ZBE 06 (4 pole) Female connector, right-angle Part No.: 6006788 ZBE 06-02 (4 pole) Female connector, right-angle with 2 m cable, Part No.: 6006790 ZBE 06-05 (4 pole) Female connector, right-angle with...
Page 20
EDS 3400 ZBM 3100 Clamp for wall-mounting - weld-type fitting - (Material of welding bridge: QSTE340TM, zinc coating EN 12329 FE/ZN8/B; Material of lower section: TPE Santoprene 10187; Material of top section: Steel strip DIN 95381-1.4571) Part No.: 3184632 ZBM 3200...