Advance Planning; Grounding The Appliance - GE ZKD910 Installation Instructions Manual

Table of Contents

Advertisement

• The drawer may be installed below a
Advance
Planning
• The warming drawer can be installed below
• The warming drawer can be installed below
IMPORTANT - (Please read carefully)
Grounding
the
FOR PERSONAL SAFETY, THIS APPLIANCE
MUST BE PROPERLY GROUNDED.
Appliance
Do not use an extension cord or adapter plug
with this appliance. Follow National electrical
codes or prevailing local codes and ordi-
nances.
This warming drawer must be supplied with
120V, 60Hz, and connected to an individual,
properly grounded branch circuit, and
protected by a 15 or 20 amp circuit breaker or
time delay fuse.
• A properly grounded 3-prong receptacle
• Locate the receptacle in an adjacent cabinet.
• When two warming drawers are installed
countertop, a cooktop, a single or double
oven and side by side using 2 drawers.
approved cooktops. Allow 2" min. clearance
from bottom of cooktop burner box to top
of warming drawer cutout. See page 5.
approved ovens. Allow a 2" min. clearance
between cutouts. Additional clearances may
be required. See page 6.
should be located within reach of the
drawers' 56" long power cord.
– within 42" of the right side or,
– within 16" of the left side or,
– A recessed receptacle may be located on
the right side of the cutout, 7" from the
back of the cabinet. In this location, the
excess power cord should be coiled and
secured to the warming drawer side with
the power cord clip.
side to side, they can operate from the same
receptacle.
Design Information
Warming Drawer
• Electrical power cord is located on the right
side of the warming oven. Locate the outlet
within reach of the 56" long power cord in
an adjacent cabinet, within 42" of the right
side or 16" from the left side of the cutout. A
recessed receptacle can be installed on the
right side of the cutout, 7" max. from the
rear of cabinet.
IMPORTANT: (Please read carefully).
The power cord of this appliance is equipped
with a three-prong (grounding) plug that
mates with a standard three-prong grounding
wall receptacle to minimize the possibility of
electric shock. The customer should have the
wall receptacle and circuit checked by a
qualified electrician to make sure the recep-
tacle is properly grounded and has the correct
polarity.
• Where a standard two-prong wall receptacle
is encountered, it is the personal responsibil-
ity and obligation of the customer to have it
replaced with a properly grounded three-
prong wall receptacle.
Do not, under any circumstances, cut or
remove the third (ground) prong from the
power cord.
DO NOT USE AN EXTENSION CORD.
Recessed
Receptacle 7"
Max. From Rear
on Right Side.
Drill 1-1/2" Hole
For Power Cord For
Left or Right Side
Outlet Location
4