Vmac RAPTAIR60 Technical Support

Error codes and symptoms
Hide thumbs Also See for RAPTAIR60:

Advertisement

System or Parts affected

RAPTAIR60 - without Cold Climate kit (D600003)
RAPTAIR60 - with Cold Climate kit (D600004)
Index
System or Parts affected ............................................................. 1
Overview ....................................................................................... 1
Error Message Table .................................................................... 3
Warning Message Table ........................................................... 4
Trouble Shooting Table ............................................................... 5
Modifying System Parameters .................................................... 6
Factory Reset ............................................................................ 6
Wiring ............................................................................................ 8
Main Wire Diagram ................................................................... 8
Control Panel and Relay Wire Diagram .................................... 9

Overview

A quick reference for error codes, symptoms, trouble shooting and wire diagrams.
If an error is present, the RAPTAIR60 unit WILL NOT start the compressor until the error is
cleared. When an error is present the WARNING LED will flash on/off and the screen will
display 'ERRORS DETECTED' followed by the following list of errors. The user MUST
scroll through ALL the displayed errors by pressing the NEXT button before the unit can
re-try the start sequence.

Entering DIAGNOSTIC MODE to Retrieve Logged Errors

1) Key on the system but do not start. No error messages on the display box should be shown.
2) Press the "NEXT" and "BACK" buttons for 5 seconds to enter Diagnostics Mode.
3) Press the "NEXT" and "BACK" buttons to scroll to "VIEW LOGGED ERRORS".
4) Press the "ON/ENTER" button to view the errors.
5) Use "NEXT" and "BACK" to scroll through the errors. Fill in all of the blank boxes on the following
table.
The tables below represent the lines that will be shown on the control box display. Completely fill in all of
the blanks on the following tables. (Figure 1 provides an example of an error message)
Document
Version
Department
EXT-D60-002
A
Knowledge Base:
www.kb.vmacair.com
Email:
tech@vmacair.com
Web:
www.vmacair.com
Technical Support:
1(888)241-2289
Toll
Free:1(800)738-8622
Fax: 1(877)740-3202
Technical Support
Subject
RAPTAIR60 Error Codes and Symptoms
Revision Details
Tech
Document Release
Revised by
Tech
SP 27 Aug 2015
BC 27 Aug 2015
Engineering
Implemented
N/A
27 Aug 2015
Page 1 of 9

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RAPTAIR60 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vmac RAPTAIR60

  • Page 1: Table Of Contents

    A quick reference for error codes, symptoms, trouble shooting and wire diagrams. If an error is present, the RAPTAIR60 unit WILL NOT start the compressor until the error is cleared. When an error is present the WARNING LED will flash on/off and the screen will display ‘ERRORS DETECTED’...
  • Page 2 Technical Support Subject RAPTAIR60 Error Codes and Symptoms Figure 1 Name: __________________________ Phone#: ______________________ Company: _______________________ Email/Fax#:____________________ Date: ___________________________ Please complete the sheet below and email to tech@vmacair.com. (A clear picture of this filled in sheet can be emailed if that is easier).
  • Page 3: Error Message Table

    Technical Support Subject RAPTAIR60 Error Codes and Symptoms Error Message Table Error Error Message Displayed Cause Code COMP TEMP SENSOR Temperature sensor on the compressor is unplugged FAILED – OPEN or wire to control box has been cut. COMP TEMP SENSOR Temperature sensor on the compressor is shorted.
  • Page 4: Warning Message Table

    Technical Support Subject RAPTAIR60 Error Codes and Symptoms DISPLAY CANBUS A CAN bus error between the Display box and CONN ERROR Control box. End of errors screen. Pressing ENTER will try to End of Errors OK to Retry? restart the system.
  • Page 5: Trouble Shooting Table

    Technical Support Subject RAPTAIR60 Error Codes and Symptoms Trouble Shooting Table Symptom Possible Cause Corrective Action Pressure control line plugged Remove and clear the line or frozen Frequent relief valve Wait for system blow-down or operation System still at high pressure...
  • Page 6: Modifying System Parameters

    Pressing NEXT will show CONFIRM RESET? Pressing BACK will display CANCEL again  Select the desired option and press the ENTER button For details and an explanation for adjusting system parameters, see section 7.7 Adjusting System Parameters in the RAPTAIR60 Installation and User’s Manual. Setting Description Adjustment Default 0.5, 1, 2, 5, 10, 15, 30...
  • Page 7 Technical Support Subject RAPTAIR60 Error Codes and Symptoms Setting Description Adjustment Default In Standby, allow the Allow Low Battery engine to restart Enabled/Disabled Enabled Restart based on low battery level Engine will restart if 10.0 – 14.0V @ 0.1V Battery Restart Lower below this threshold 12.1V...
  • Page 8: Wiring

    Technical Support Subject RAPTAIR60 Error Codes and Symptoms Wiring Main Wire Diagram Figure 2 Document Version Department Revision Details Revised by Tech Engineering Implemented EXT-D60-002 Tech Document Release SP 27 Aug 2015 BC 27 Aug 2015 27 Aug 2015 Page 8 of 9 Knowledge Base: www.kb.vmacair.com...
  • Page 9: Control Panel And Relay Wire Diagram

    Technical Support Subject RAPTAIR60 Error Codes and Symptoms Control Panel and Relay Wire Diagram Figure 3 Document Version Department Revision Details Revised by Tech Engineering Implemented EXT-D60-002 Tech Document Release SP 27 Aug 2015 BC 27 Aug 2015 27 Aug 2015...

This manual is also suitable for: