Acer Wood Runner Manual page 53

Table of Contents

Advertisement

GANTRY HITS END STOP
WHEN HOMING
PICKUP SCREWS
CONSISTENTLY NOT
CENTERED ON BOARD
LUMBER PILES NOT SHOWN
IN SCAN
NOISY DRIVE BELT
GANTRY DOES NOT STOP
RAPIDLY WHEN LIGHT
CURTAIN IS BROKEN BUT
BRAKE VALVE ACUATES
AIR DUMP VALVE DOES NOT
DRAIN AIR WHEN E-STOP OR
LIGHT CURTAIN ACTIVATED
PICKUP SCREW NOT
THREADING INTO BOARD FAR
ENOUGH
PICKUP SCREW MOTOR DOES
NOT SHUT OFF AFTER
THREADING INTO BOARD
SCREW MOTOR WILL NOT
RUN EVEN FROM MANUAL
SCREEN
PROBLEM WITH HOME
SWITCH
LASER ALIGNMENT
LASER OR INPUT MODULE
PROBLEM
LASER DOT NOT VISIBLE
LASER DOT VISIBLE
BELT TOO TIGHT
PULLEYS OUT OF ALIGNMENT
BRAKE PADS WORN OR BRAKE
ASSEMBLY FAULTY
STICKING DUMP VALVE
PRESSURE PAD SWITCH OUT
OF ADJUSTMENT
WRONG SCREW LENGTH
PROBLEM WITH PRESSURE
PAD SWITCH
PRESSURE PAD STICKING AND
KEEPING SWITCH ACTIVATED
AIR VALVE STICKING
AIR VALVE CABLE PROBLEM
SCREW MOTOR PROBLEM
53
HOME SWITCH GAP SET
IMPROPERLY- RESET TO 1/16"
CABLE UNPLUGGED OR
FAULTY
FAULTY SWITCH
RE-ALIGN LASER WITH LOAD
BAR- COVERED IN
ADJUSTMENT SECTION OF
MANUAL
CABLE UNPLUGGED OR
FAULTY CABLE OR FAULTY
LASER
FAULTY LASER- REPLACE
FAULTY INPUT
RE-TENSION BELT-SEE
ADJUSTMENT SECTION
REALIGN PULLEYS-SEE
ADJUSTMENT SECTION
REPLACE OR REPAIR
REPLACE
SEE ADJUSTMENT SECTION OF
MANUAL
FAULTY SWITCH, CABLE OR
SWITCH OUT OF
ADJUSTMENT
REPAIR
REPLACE
REPLACE OR REPAIR
REPLACE OR REPAIR

Advertisement

Table of Contents
loading