Acer Wood Runner Manual page 52

Table of Contents

Advertisement

E-STOP CONDITION WILL NOT
RESET- SEE SAFETY SYSTEM
SECTION OF MANUAL FOR
DETAILED EXPLANATION OF
SAFETY SYSTEM
LOW AIR PRESSURE
NOTIFICATION ON SCREEN
BUT INCOMING AIR PRESSURE
CORRECT - SEE AIR SUPPLY
ASSEMBLY SECTION OF
MANUAL
ONE OF THE AIR VALVES WILL
NOT OPERATE EVEN FROM
MANUAL SCREEN
INFEED DECK MOTORS WILL
NOT OPERATE EVEN FROM
MANUAL SCREEN
LIGHT CURTAIN NOT ALIGNED
E-STOP SWITCH PUSHED IN
OR FAULTY
BRAKE BEAM NOT ALIGNED
FAULTY CABLE ON LIGHT
CURTAIN OR BRAKE BEAM
I/O CABLE UNPLUGGED OR
FAULTY TO OPERATORS
CONSOLE OR GANTRY
FAULTY SAFETY RELAY
SAFETY LOCKOUT VALVE
CLOSED
DUMP VALVE NOT OPENING
FILTER PLUGGED
PRESSURE SWITCH PROBLEM
CABLE PROBLEM
VALVE PROBLEM
MOTOR CIRCUIT BREAKER.
TRIPPED
OVERLOAD TRIPPED
FAULTY MOTOR CONTACTOR
WIRING PROBLEM TO MOTOR
FAULTY MOTOR
52
SEE LIGHT CURTAIN
ALIGNMENT IN SAFETY
SYSTEM SECTION
PULL OUT SWITCH OR
REPLACE
SEE BRAKE BEAM ALIGNMENT
IN SAFETY SYSTEM SECTION
REPAIR CABLE
PLUG CABLE IN OR REPLACE
CABLE
REPLACE
OPEN VALVE
CABLE TO DUMP VALVE
UNPLUGGED. FAULTY CABLE
OR FAULTY DUMP VALVE
REPLACE FILTER
CABLE UNPLUGGED. FAULTY
PRESSURE SWITCH OR FAULTY
CABLE
CABLE UNPLUGGED OR
FAULTY
VALVE FAULTY- REPLACE
CHECK FOR JAM CONDITION
OR GEARBOX PROBLEM
RESET OVERLOAD
REPLACE CONTACTOR
REPAIR
REPLACE MOTOR

Advertisement