Checking The Secondary Circuit Temperature Limiter - Viessmann Vitosorp 200-F Installation Instructions For Contractors

Gas adsorption heating appliance natural gas and lpg version
Hide thumbs Also See for Vitosorp 200-F:
Table of Contents

Advertisement

Checking the pressure sensor
7.0
0.7
5.0
0.5
3.0
0.3
1.0
0.1
-0.1
-1.0
20
0
10
Value in "Diagnosis"
Fig. 66
Permissible range
A

Checking the secondary circuit temperature limiter

For the installation position in the appliance, see dia-
gram on page 103.
If the burner control unit cannot be reset after a fault
shutdown, even though the secondary circuit flow tem-
perature is below approx. 75 °C, check the following:
1. Pull the leads from the temperature limiter.
2. Check continuity of the temperature limiter with a
multimeter.
(cont.)
Fault "E6"
40
60
80
100
30
50
70
90
A
120
140
160
110
130
150
170
3. Remove faulty temperature limiter.
4. Coat the new temperature limiter with heat con-
ducting paste and install it.
5. After commissioning, press reset button R on the
Vitotronic control unit.
6. If the fault persists:
Check high limit safety cut-out.
Maintenance