E-Mail: info@amadaweldtech.com NOTICE AMADA WELD TECH may be released from all warranty obligations if repairs or modifications are made by persons other than its own service personnel, or its authorized representatives, unless such repairs or modifications are specifically authorized in writing by AMADA WELD TECH INC.
1. Applicability. (a) These terms and conditions of sale (these “Terms”) are the only terms which govern the sale of the goods (“Goods”) by Amada Weld Tech Inc. (“Seller”) to the buyer identified in the Sales Quotation and/or Acknowledgment (as each defined below) to which these Terms are attached or incorporated by reference (“Buyer”).
Page 6
7. Inspection and Rejection of Nonconforming Goods. (a) Buyer shall inspect the Goods within two (2) days of receipt (“Inspection Period”). Buyer will be deemed to have accepted the Goods unless it notifies Seller in writing of any Nonconforming Goods during the Inspection Period and furnishes such written evidence or other documentation as required by Seller.
Page 7
(c) All patents, trademarks, copyrights or other intellectual property rights embodied in the Goods, including without limitation the Software, are owned by Seller and its licensors. Seller and its licensors retain all right, title and interest in such intellectual property rights. Except as expressly set forth herein, no license rights or ownership in or to any of the foregoing is granted or transferred hereunder, either directly or by implication.
Page 8
(c) ALL WARRANTIES SET FORTH HEREIN, DIRECT OR IMPLIED, ARE VOIDED IF THE INITIAL INSTALLATION AND START-UP OF THE SUBJECT GOOD IS NOT SUPERVISED BY AN AUTHORIZED REPRESENTATIVE OF SELLER. AFTER INSTALLATION, ANY RE-ALIGNMENT, RE-CLEANING, OR RE-CALIBRATION, PROVIDED THEY ARE NOT RELATED TO A PROVEN DEFECT IN MATERIALS OR WORKMANSHIP, SHALL BE PERFORMED BY AN AUTHORIZED REPRESENTATIVE OF SELLERAT THE CURRENT SERVICE RATES.
Page 9
20. Assignment. Buyer shall not assign any of its rights or delegate any of its obligations under this Agreement without the prior written consent of Seller. Any purported assignment or delegation in violation of this Section 20 is null and void. No assignment or delegation relieves Buyer of any of its obligations under this Agreement.
The GP-500A-Plus Inert Gas Purification System is a self-contained unit, designed to recirculate the atmosphere in a controlled atmosphere enclosure to remove moisture and oxygen. The system is designed to be used with AMADA WELD TECH Gloveboxes but may be sold as a stand-alone system and incorporated in the enclosures of different manufacturers.
Service Requirements Power Single-Phase, 208 – 240 VAC, 20 A, 50/60 Hz 5% Hydrogen / 95% Nitrogen (at least 270 cu ft. / regeneration) Regeneration 3/8” polyflow tube. Forming Gas CAUTION: A Hydrogen concentration > 5% will cause damage to the System. Regeneration 100% Nitrogen or Argon (at least 15 cu ft / regeneration), 3/8”...
Installation Please refer to the Pneumatic Schematic for the internal piping: 105-00299-000 – GP-500A-Plus Automatic Dual Column Gas Purifier Pneumatic Schematic Please refer to the Electrical Schematic for the electrical connections: 105-00300-000 – GP-500A-Plus Automatic Dual Column Gas Purifier Electrical Schematic The GP-500A-Plus Inert Gas Purification System circulation inlet and outlet are connected to the enclosure with fixed tubing.
Gas Dryer Controls & Operation 1. Initial Set-up: Before the GP-500A-Plus can begin operation the enclosure must have a humidity level of –25 dp°C or drier and following must be properly connected: • Electrical Power • Circulation Inlet and Exhaust •...
To adjust the date and time, press the onscreen button for each item that needs adjustment. Figure 3 shows the locations of the Date and Time Adjustment Screen onscreen buttons. Current Date & Time Month, Day, Year and Set Date MM / DD / YY 05/20/08 Hour, Minute, Second and Set Time...
The touchscreen display is graphically divided in half (Figure 6). The top section shows the temperature in Celsius and the status of Column 1. The bottom section shows the same for Column 2. Any errors will display in the status field of the affected column. Column 1 22.3C –...
Circulation Note: Only one column may circulate at any given time. Note: A column cannot purge and circulate at the same time. An error will be displayed if the user attempts to do so. Note: A column in standby can begin and end circulating while the other column is in standby or purging. To begin circulation, press either the C1 Circ (Column 1 Circulation) or C2 Circ (Column 2 Circulation).
Circ: 00/00/00 00:00:00 Purge: 00/00/00 00:00:00 Circ: 00/00/00 00:00:00 Purge: 00/00/00 00:00:00 Main Menu Figure 10: Last Cycle Screen 5. System Errors: The GP-500A-P will monitor sensors throughout operation to detect errors. When an error is detected, the user will be notified graphically through the touchscreen interface’s LCD Display. Table 1 contains a list of possible system errors, their causes, and common actions to remedy them.
Technician Guide: Initial set-up of Control System 1. Installing Development Software Software used to setup the Koyo DirectLOGIC06 (Automation Direct #D0-06DD2) PLC and C-More Touchscreen (Automation Direct #EA1-S3ML) are as follows: • DirectSOFT V4.0 Build 25 • C-more micro Programming Software V1.20.7.40 When installing the development software on the PC Host, choose the default settings when possible.
Locate the plc.PRJ project file and click Open If prompted, select “Use Disk” If “Set PID table address” window does not pop up, select “View” from the menu bar and then “PID View” Input V2000 into Table Start Address and 1 into Number of Loops, click Update and Exit 10.
4. Altering System Behavior This section will describe how to make simple changes to the system behavior by manipulating values loaded into the DirectLOGIC06 PLC. Connect the PLC to the Host PC as detailed in the PLC SETUP section of this manual and perform steps 1 &...
Page 21
• Cooled Down Temperature Temperature (in 10ths of a degree Celsius) that controls the threshold between cooled and not cooled for both columns (Memory location: V4002, Default: 50°C). • Valve Delay Timer Length of time (in 10ths of a second) the system will delay after commanding the circulation valves to be closed or opened before checking the valves for doing so (Memory location: V4004, Default: 10 seconds).
Page 22
• Deciseconds per Minute Length of time (in 10ths of a second) the system will wait before incrementing the minute counter (Memory location: V4040, Default: 59.9 seconds) • Error Display Time Length of time (in 10ths of a second) the system will display non-fatal errors (Memory location: V4050, Default: 10 seconds) •...