Message Codes

Me s s a g e Co d e s
Laser
ON/OFF
ON/blinks
OFF
blinks
blinks
blinks every 5 sec
blinks every 5 sec
Makita SK700D/SK700GD
LED
lights red
lights orange
blinks red
blinks red
lights red
lights red
blinks green
Cause
Instrument has low power
Instrument is close to temperature limit. In
very hot environments it can be that maximum
two lines work simultaneously.
Temperature alert
Instrument is out of self-levelling range
Instrument is out of self-levelling range and
has low power
Levelling lock is activated but instrument has
low power
Levelling lock is activated for working without
self-levelling
Correction
Charge Li-Ion battery
Cool down instrument
Cool down or heat up instrument
Place the instrument almost horizontal and
self-levelling will start automatically
Charge Li-Ion battery
Charge Li-Ion battery