Advertisement
Accuracy with favourable conditions * | ± 2.0 mm / ± 0.08 in *** |
Accuracy with unfavourable conditions ** | ± 3.0 mm / ± 0.12 in *** |
Range with favourable conditions * | 0.2-30 m / 0.6-98 ft |
Range with unfavourable conditions ** | 0.2-20 m / 0.6-66 ft |
Smallest unit displayed | 1 mm / 0.04 in |
Laser class | 2 |
Laser type | 635 nm, < 1 mW |
Ø laser point at distances | 6 / 18 mm 10 / 30 m |
Protection class | IP54 |
Autom. laser switch off | after 90 s |
Autom. power switch-off | after 180 s |
Battery durability (2 x AAA) | up to 5000 measurements |
Dimension (H x D x W) | 115 x 53 x 25 mm 4.5 x 2.14 x 1 in |
Weight (with batteries) | 95 g / 3.4 oz |
Temperature range:
| -25 to 70°C -13 to 158°F 0 to 40°C 32 to 104°F |
* favourable conditions are: white and diffuse reflecting target (white painted wall), low background illumination and moderate temperatures.
** unfavourable conditions are: targets with lower or higher reflectivity or high background illumination or temperatures at the upper or lower end of the specified temperature range.
*** Tolerances apply from 0.2 m to 5 m with a confidence level of 95%.
With favourable conditions the tolerance may deteriorate by 0.1 mm/m for distances above 5 m.
With unfavourable conditions the tolerance may deteriorate by 0.15 mm/m for distances above 5 m.
If the message Error does not disappear after switching on the device repeatedly, contact the dealer.
If the message InFoappears with a number, press the Clear button and observe the following instructions:
No. | Cause | Correction |
204 | Calculation error | Perform measurement again. |
252 | Temperature too high | Let device cool down. |
253 | Temperature too low | Warm device up. |
254 | Battery voltage too low for measurements | Change batteries. |
255 | Received signal too weak, measuring time too long | Change target surface (e.g.white paper). |
256 | Received signal too high | Change target surface (e.g.white paper). |
257 | Too much background light | Shadow target area. |
258 | Measurement outside of measuring range | Correct range. |
260 | Laser beam interrupted | Repeat measurement. |
Wavelength | 635 nm |
Maximum radiant output power used for classification | 0.95 mW |
Pulse repetition frequency | 320 MHz |
Pulse duration | >400ps |
Beam divergence | 0.16 mrad x 0.6 mrad |
The person responsible for the instrument must ensure that all users understand these directions and adhere to them.
Responsibilities of the manufacturer of the original equipment:
Makita Corporation Anjo, Aichi 446-8502 Japan /
Makita, Jan-Baptist Vinkstraat 2, 3070, Belgium
Internet: www.makita.com
The company above is responsible for supplying the product, including the User Manual in a completely safe condition.
The company above is not responsible for third party accessories.
Responsibilities of the person in charge of the instrument: