Connecting Regulator Hose Assembly To Lp Gas Cylinder; Connecting Regulator Hose Assembly To Cooker; Gas Leak Test - Bayou Classic SP31 Owner's Manual

Table of Contents

Advertisement

CONNECTING REGULATOR HOSE ASSEMBLY TO LP GAS CYLINDER

1. Check that cylinder is upright and the valve is closed by turning
the knob clockwise.
2. Remove the protective safety cap from the cylinder valve and the
Type-1 Coupling Nut on the regulator
3. Insert the nipple of the large coupling nut into cylinder valve outlet.
Insure that the coupling nut is centered properly.
4. Turn the large coupling nut clockwise by hand and tighten
to a full stop. Take care not to cross thread the coupling nut
onto the cylinder valve. Do not use tools to tighten connection.
NOTE: If you are unable to make the connection,
repeat steps 3 and 4.
5. Check that the hose does not contain kinks, does not come into contact with sharp edges, and does not contact surfaces
that may become hot during use.
6. Leak check all fittings before lighting cooker. See section on "Gas Leak Test Instructions" on page 13.

CONNECTING REGULATOR HOSE ASSEMBLY TO COOKER

The Regulator Hose Assembly is a pre-assembled unit.
Do not take apart. Simply connect the regulator hose
assembly to the LP gas cylinder and to the cooker. An
adjustable wrench is needed when attaching the hose to
the burner. Visually inspect the regulator hose assembly
prior to each use. If there is evidence of abrasion, wear,
cuts or leaks, the hose must be replaced prior to the
appliance being put into operation.

GAS LEAK TEST

WARNING
WHEN TO PERFORM A LEAK TEST
• After assembling your cooker and before lighting for the first time, even if purchased fully assembled.
• Every time the LP gas cylinder is refilled or if any of the gas components are replaced.
• Any time your cooker has been moved.
• At least once per year or if your cooker has not been used for more than 60 days.
DANGER
GAS LEAK TESTING
To prevent fire or explosion hazard:
• DO NOT smoke or permit ignition sources in the area while conducting a leak test.
• Perform test OUTDOORS only in a well ventilated area.
• Never perform a leak test with a match or open flame.
• Never perform a leak test while the cooker is in use or while cooker is still hot.
Upright
position
Attach hose connector to the burner
in one of two ways as shown below.
Turn Air Control Shutter to
adjust flame quality
Screws may need tightening
DO NOT over tighten!
12
Turn Brass Valve
CLOCKWISE
to OFF position
Turn Coupling Nut
CLOCKWISE
to Attach
Hand Tighten!
Turn CLOCKWISE
Wrench Tighten

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ss31

Table of Contents