www.seagate.com
2.8
Environmental specifications
This section provides the temperature, humidity, shock, and vibration specifications for Barracuda drives. Ambient
temperature is defined as the temperature of the environment immediately surrounding the drive. Above 1000ft. (305
meters), the maximum temperature is derated linearly by 1°C every 1000 ft. Refer to
measurement location.
2.8.1 Ambient Temperature
Non-operating (Ambient)
Operating ambient (min °C)
Operating (Drive case max °C)
†
Seagate does not recommend operating at sustained case temperatures above 60°C.
Operating at higher temperatures will reduce useful life of the product.
2.8.2 Temperature gradient
Operating
20°C per hour (68°F per hour max), without condensation
Non-operating
30°C per hour (54°F per hour max)
2.8.3 Humidity
2.8.3.1
Relative humidity
Operating
5% to 90% non-condensing (30% per hour max)
non-operating
5% to 95% non-condensing (30% per hour max)
2.8.3.2
Wet bulb temperature
Operating
30°C / 86°F (rated)
Non-operating
40°C / 104°F (rated)
2.8.4 Altitude
Operating
–304m to 3048m (–1000 ft. to 10,000 ft.)
Non-operating
–304m to 12,192m (–1000 ft. to 40,000+ ft.)
Seagate BarraCuda Product Manual, Rev. D
–40° to 70°C (–40° to 158°F)
0° (32°F)
†
60° (140°F)
Drive Specifications
for base plate
Section 3.4 on page 21
14