Power Supply Level Indicator LED

The Power Supply Level Indicator LED indicates the percentage of the power
supply load. The possible states and descriptions of the Power Supply Level
Indicator LED are listed in Table 3-2.
Segment
Number(s)
1Ð9
10
11

Power Redundancy LED

The Power Redundancy indicates the presence of redundant power supplies. The
possible states and descriptions of the PWR Status LED are listed in Table 3-3.
LED
Color
Green
Amber
Off
Table 3-2. Power Supply Level Indicator LED
LED
State
Color
Green
10Ð90% of power
load being used.
Amber
Greater than 90% of
power supply being
used.
Red
Overload condition
exists.
Table 3-3. Power Redundancy LED
State
Redundant
System has two power supplies installed and both
are providing less than 50% of their maximum load.
Non-redundant
Two power supplies are installed and at least one is
providing over 50% of its maximum load, or a fault
condition exists.
Redundancy
Only one power supply is installed.
not available
9C206-1 Power Supply Operation
Description
No action necessary.
Warns user of a potential
overload condition.
Add an additional power
supply or reduce number of
modules in the chassis.
Description