Cabletron Systems 9C106 Setup And Installation Manual

Smartswitch 9000-6 slot chassis

Advertisement

Quick Links

SmartSwitch 9000-6 Slot
9 C106 and 9C706 Chassis
Setup and Installation Guide
9031993-02

Advertisement

Table of Contents
loading

Summary of Contents for Cabletron Systems 9C106

  • Page 1 SmartSwitch 9000-6 Slot 9 C106 and 9C706 Chassis Setup and Installation Guide 9031993-02...
  • Page 3 Notice Cabletron Systems reserves the right to make changes in speciÞcations and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The hardware, Þrmware, or software described in this manual is subject to change without notice. IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION...
  • Page 4: Industry Canada Notice

    Notice FCC Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules.
  • Page 5: Declaration Of Conformity

    DECLARATION OF CONFORMITY Application of Council Directive(s): ManufacturerÕs Name: ManufacturerÕs Address: European Representative Name: European Representative Address: Conformance to Directive(s)/Product Standards: Equipment Type/Environment: We the undersigned, hereby declare, under our sole responsibility, that the equipment packaged with this notice conforms to the above directives. Manufacturer Mr.
  • Page 6 Notice...
  • Page 7: Table Of Contents

    Chapter 1 Introduction SmartSwitch 9000-6 Slot 9C106 Overview ... 1-1 9C106 Chassis ... 1-1 Features ... 1-1 The Backplane ... 1-2 9C206-1 Power Supply ... 1-4 Features ... 1-5 9C306 System Monitor ... 1-5 Features ... 1-7 How to Use This Manual ... 1-7 Related Manuals...
  • Page 8 Contents Appendix A SmartSwitch 9000-6 Slot Chassis Security Bars Installing the Security Bars ...A-1 Removing Security Bars ...A-3...
  • Page 9: Chapter 1 Introduction

    Cabletron Systems SmartSwitch 9000-6 Slot networking chassis and its associated modules. Unless noted differently, the information in this guide applies to both the 9C106 NOTE and 9C706 SmartSwitch 9000-6 Slot chassis, which are referred to as either the Ò9C106Ó...
  • Page 10: The Backplane

    Introduction The Backplane The 9C106 SmartSwitch 9000-6 Slot chassis provides six distinct backplane buses, and the 9C706 provides an additional seventh bus, the Cell Transfer Matrix. Each bus serves a particular set of needs. The seven backplane buses are shown in Figure 1-1.
  • Page 11 Local Management operations. The SMB-10 operates at Ethernet speeds of 10 Mbps, and is connected to any manageable module in the chassis. Access to the SMB-10 for Local Management operations is provided through an Ethernet Port Interface Module (EPIM) slot on the 9C306 System Monitor, or through the serial COM ports, also located on the System Monitor.
  • Page 12: 9C206-1 Power Supply

    9C206-1 Power Supply The 9C206-1 power supply, shown in Figure 1-2, is a 1000 watt, triple output supply that provides power to the SmartSwitch 9000-6 Slot chassis. At least one power supply must be installed; however, an additional power supply can be installed to achieve redundancy.
  • Page 13: Features

    50/60 Hz. In addition, power factor correction circuitry is employed to limit harmonic distortion of the ac mains. Hot Swapping 9C206-1 power supplies can be installed or removed from the front of the chassis while another power supply is operating without affecting network operation. LANVIEW LEDs...
  • Page 14 Introduction 9C306 STATUS EPIM Figure 1-3. The 9C306 System Monitor...
  • Page 15: Features

    System Monitor. How to Use This Manual To gain a full understanding of the 9C106 chassis and its capabilities, and to help eliminate any potential problems during or after installation, read and understand all of the instructions in this document before attempting to install the SmartSwitch 9000-6 Slot chassis.
  • Page 16: Related Manuals

    Guide In addition, each Interface Module has a speciÞc UserÕs Guide and Local Management Appendix. , provides an overview of the 9C106 and 9C706 chassis, Chassis Installation , describes the functions of the , provides detailed physical, environmental, and safety...
  • Page 17: Getting Help

    Getting Help For additional support related to this device or document, contact Cabletron Systems using one of the following methods: World Wide Web Phone Internet mail Login Password To send comments or suggestions concerning this document, contact the Cabletron Systems Technical Writing Department via the following email address: TechWriting@cabletron.com Make sure to include the document Part Number in the email message.
  • Page 18 Introduction 1-10...
  • Page 19: Chapter 2 Smartswitch 9000-6 Slot Chassis Installation

    ¥ The site must have an unrestricted free surface area around the SmartSwitch 9000-6 Slot chassis, allowing for free movement of air. An open space of at least 84 high by 63.5 wide by 81.24 centimeters deep (29.5 high by 25 wide by 24 inches deep) is the minimum recommended.
  • Page 20: Unpacking The Smartswitch 9000-6 Slot Chassis

    (Save the shipping box and packing materials in the event the chassis must be reshipped.) 2. Remove the chassis from the protective plastic bag. (Save the bag in the event the unit must be reshipped.) 3. Examine the SmartSwitch 9000-6 Slot carefully, checking for damage. If any damage is noted, DO NOT install the chassis.
  • Page 21: Rack Mounting The Smartswitch 9000-6 Slot Chassis

    Two people may be required to lift the chassis into place. The chassis is secured with ten bolts, Þve on each side. Using the bolts provided with the rack, bolt the chassis to the rack, starting with the bottom holes and working up, as shown in Figure 2-1.
  • Page 22 SmartSwitch 9000-6 Slot Chassis Installation 9C406 Figure 2-1. Rack Mounting the Chassis...
  • Page 23: Installing A Power Supply

    6 Slot chassis. An additional power supply can be added to achieve redundancy. A power supply is installed by plugging it into either the left or right power supply slot on the front of the SmartSwitch 9000-6 Slot chassis, as shown in Figure 2-2.
  • Page 24 SmartSwitch 9000-6 Slot Chassis Installation c. Firmly plug the power supply into the corresponding connector on the back of the chassis by pushing the power supply until its frame touches the surface of the SmartSwitch 9000-6 Slot chassis. d. Do not force the power supply in place. If significant resistance is encountered before the frame is flush with the chassis, remove the power supply, realign it, and push it in again.
  • Page 25: Installing The 9C306 System Monitor

    4. Examine it carefully, checking for damage. If any damage exists, DO NOT install it. Immediately contact Cabletron System. 5. Install the System Monitor Module in the chassis slot marked SM, as shown in Figure 2-3. Slide the module between the module guide. Take care that the module slides in straight and properly engages the backplane connectors.
  • Page 26: Installing A Fan Module

    Installing a Fan Module Only qualiÞed personnel should perform installation procedures. The Fan module can only be installed in the slot at the top of the chassis, as shown in Figure 2-4. Install the Fan Module by following the steps below: 1.
  • Page 27 4. Hold the sides of the Fan Module. 5. Line up the rails on the Fan Module with the tracks on the chassis. 6. Slide the Fan Module into the chassis until it is completely seated. 7. Secure the Fan Module into the chassis by tightening the slotted screws.
  • Page 28: Installing Smartswitch 9000-6 Slot Interface Modules

    Figure 2-3. Take care that the Interface Module slides in straight and properly engages the backplane connectors.
  • Page 29: Powering Up The Smartswitch 9000-6 Slot Chassis

    Powering Up the SmartSwitch 9000-6 Slot Chassis Power up the SmartSwitch 9000-6 Slot chassis by following the steps below: NOTE If two power supplies are installed, repeat the procedure below for each supply. 1. Plug one end of the power cord (supplied with the power supply) into the ac power socket on the lower right front corner of the power supply.
  • Page 30 SmartSwitch 9000-6 Slot Chassis Installation 2-12...
  • Page 31: 9C206-1 Power Supply Operation

    9C206-1 Power Supply Operation This chapter describes the operation of the SmartSwitch 9000-6 Slot chassis power supply. The chapter also details the use of LANVIEW LEDs for troubleshooting and status information. The 9C206-1 power supply can operate with input voltages ranging from 100Ð250 Vac at 50/60 Hz.
  • Page 32: Pwr Status Led

    9C206-1 Power Supply Operation Redundancy PWR Status LED Power Supply Level Indicator Figure 3-1. 9C206-1 Power Supply LANVIEW LEDs PWR Status LED The PWR Status LED indicates the input and output status of a power supply. The possible states and descriptions of the PWR Status LED are listed in Table 3-1. LED Color Green Functional...
  • Page 33: Power Supply Level Indicator Led

    50% of its maximum load, or a fault condition exists. Only one power supply is installed. 9C206-1 Power Supply Operation Description No action necessary. Warns user of a potential overload condition. Add an additional power supply or reduce number of modules in the chassis. Description...
  • Page 34 9C206-1 Power Supply Operation...
  • Page 35: Chapter 4 Specifications

    Electromagnetic Compatibility (EMC): FCC Part 15, VCCI V-3, CSA C108.8, EN 50082-1, 89/336/EEC, and EN 55022 9C106 SmartSwitch 9000-6 Slot Chassis Dimensions 66 H x 43.2 W x 40.6 D centimeters (26 H x 17 W x 16 D inches)
  • Page 36: 9C706 Smartswitch 9000-6 Slot Chassis

    Specifications 9C706 SmartSwitch 9000-6 Slot Chassis Dimensions 66 H x 43.2 W x 40.6 D centimeters (26 H x 17 W x 16 D inches) Weight Unit: Shipping: 16.82 kilograms (37 pounds) 9C206-1 Power Supply Dimensions 48.3 H x 10.7 W x 36.8 D centimeters (19 H x 4.2 W x 14.5 D inches)
  • Page 37: Installing The Security Bars

    Figure A-2. 3. Secure the bottom security bar to the chassis with the screws that are built into the security bar assembly.
  • Page 38 5. Slide the security bar up, so that the holes of the securing tabs are aligned with the join in the beveled corners of the interface modules. 6. Secure the top security bar to the chassis with the screws that are built into the security bar assembly.
  • Page 39: Removing Security Bars

    Slide the security bars out from behind the interface module plastic tabs. Be sure to remove both security bars before attempting to remove any interface modules from the chassis. Set the security bars aside for re-installation. Security Bar Interface Module...
  • Page 40 SmartSwitch 9000-6 Slot Chassis Security Bars...

This manual is also suitable for:

9c706

Table of Contents